Kemper, M; Haas, T; Imach, S; Weiss, M (2014). Intubation über den Tubuswechsler an einem Intubationstrainer. Der Anästhesist, 63(7):563-567.

Abstract

BACKGROUND Securing the airway using a tube exchanger catheter is an important and useful technique in anesthesia. Its success is mainly hampered by tube tip impingement of laryngeal structures. Advancing the tracheal tube along its normal curvature via a tube exchanger catheter has a high risk of tube tip impingement mainly of right laryngeal structures. The authors achieved successful clinical experience by rotating the tracheal tube 90° anticlockwise (ventral tube tip position) before railroading the tube via a tube exchanger catheter or a fiber optic bronchoscope through the larynx. AIM The aim of the study was to investigate the influence of the tracheal tube tip position while intubating an airway trainer over a tube exchange catheter. MATERIAL AND METHODS Volunteer anesthetists with varying years of professional experience were asked to intubate an intubation mannequin (Laerdal Airway Management Trainer) using the orotracheal route with an established tube exchange catheter (Cook Airway Exchange Catheter, 11F). Two different brands of tracheal tubes (Rüsch and Covidien, ID 7.0 mm) were used in a randomized order, each with the tracheal tube tip at first positioned right (90°), then ventrally (0°), left (270°) and finally dorsally (180°), resulting in eight intubation attempts for each participant. To ensure the correct tube tip position the tube was withdrawn before every intubation attempt until the tube tip position was visualized. The oropharnyx, larynx, trachea and tube were sufficiently lubricated with silicon spray (Rüsch Silikospray). The tube and airway exchange catheter size selection were made according to the clinical trial of Loudermilk et al. Successful endotracheal intubation without resistance was recorded for each tube tip position and tracheal tube brand. RESULTS In total 20 anesthetists (13 consultants and 7 residents) with a median of 9.5 years (range 3-37 years) of professional experience participated in the study. Overall 160 intubation attempts were performed, 2 participants showed no successful intubation attempts at all and 38 out of 160 intubation attempts (23.8 %) were successful. Intubation success with the tracheal tube tip placed ventrally (0°) was 60 % followed by the left (270°) and right (90°) tracheal tube tip positions with 27.5 % and 7.5 % intubation success, respectively. With the tube tip placed dorsally (180°) none of the 40 intubation attempts were successful. Intubation attempts with the Rüsch tube were more successful (28.8 %) than those with the Covidien tube (18.8 %). Placing the tracheal tube tip ventrally, the Rüsch tube was twice as successful as the Covidien tube with 16 (80 %) versus 8 attempts (40 %, p = 0.011). There was no correlation between professional experience and intubation success (p = 0.362). CONCLUSION Tube insertion via an airway exchange catheter or a fiberoptic bronchoscope is a basic technique in anesthesia. Knowledge about the difficulties and their prevention are essential for every anesthetist. The gap between the airway exchange catheter, the fiber bronchoscope and the tube diameters is one of the major reasons for tube tip impingement. This investigation showed that intubation success via a tube exchange catheter, as investigated in an intubation mannequin, is considerably influenced by the tracheal tube tip position. A 90° anticlockwise rotation, placing the tracheal tube tip ventrally, considerably increased intubation success. This is of particular importance if an anesthesia department has no appropriately sized tube exchange catheters or fiber bronchoscope for every age group of patients.

BACKGROUND Securing the airway using a tube exchanger catheter is an important and useful technique in anesthesia. Its success is mainly hampered by tube tip impingement of laryngeal structures. Advancing the tracheal tube along its normal curvature via a tube exchanger catheter has a high risk of tube tip impingement mainly of right laryngeal structures. The authors achieved successful clinical experience by rotating the tracheal tube 90° anticlockwise (ventral tube tip position) before railroading the tube via a tube exchanger catheter or a fiber optic bronchoscope through the larynx. AIM The aim of the study was to investigate the influence of the tracheal tube tip position while intubating an airway trainer over a tube exchange catheter. MATERIAL AND METHODS Volunteer anesthetists with varying years of professional experience were asked to intubate an intubation mannequin (Laerdal Airway Management Trainer) using the orotracheal route with an established tube exchange catheter (Cook Airway Exchange Catheter, 11F). Two different brands of tracheal tubes (Rüsch and Covidien, ID 7.0 mm) were used in a randomized order, each with the tracheal tube tip at first positioned right (90°), then ventrally (0°), left (270°) and finally dorsally (180°), resulting in eight intubation attempts for each participant. To ensure the correct tube tip position the tube was withdrawn before every intubation attempt until the tube tip position was visualized. The oropharnyx, larynx, trachea and tube were sufficiently lubricated with silicon spray (Rüsch Silikospray). The tube and airway exchange catheter size selection were made according to the clinical trial of Loudermilk et al. Successful endotracheal intubation without resistance was recorded for each tube tip position and tracheal tube brand. RESULTS In total 20 anesthetists (13 consultants and 7 residents) with a median of 9.5 years (range 3-37 years) of professional experience participated in the study. Overall 160 intubation attempts were performed, 2 participants showed no successful intubation attempts at all and 38 out of 160 intubation attempts (23.8 %) were successful. Intubation success with the tracheal tube tip placed ventrally (0°) was 60 % followed by the left (270°) and right (90°) tracheal tube tip positions with 27.5 % and 7.5 % intubation success, respectively. With the tube tip placed dorsally (180°) none of the 40 intubation attempts were successful. Intubation attempts with the Rüsch tube were more successful (28.8 %) than those with the Covidien tube (18.8 %). Placing the tracheal tube tip ventrally, the Rüsch tube was twice as successful as the Covidien tube with 16 (80 %) versus 8 attempts (40 %, p = 0.011). There was no correlation between professional experience and intubation success (p = 0.362). CONCLUSION Tube insertion via an airway exchange catheter or a fiberoptic bronchoscope is a basic technique in anesthesia. Knowledge about the difficulties and their prevention are essential for every anesthetist. The gap between the airway exchange catheter, the fiber bronchoscope and the tube diameters is one of the major reasons for tube tip impingement. This investigation showed that intubation success via a tube exchange catheter, as investigated in an intubation mannequin, is considerably influenced by the tracheal tube tip position. A 90° anticlockwise rotation, placing the tracheal tube tip ventrally, considerably increased intubation success. This is of particular importance if an anesthesia department has no appropriately sized tube exchange catheters or fiber bronchoscope for every age group of patients.

Citations

1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Other titles:Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation
Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
Dewey Decimal Classification:610 Medicine & health
Language:German
Date:July 2014
Deposited On:28 Nov 2014 12:17
Last Modified:05 Apr 2016 18:33
Publisher:Springer
ISSN:0003-2417
Publisher DOI:https://doi.org/10.1007/s00101-014-2342-7
PubMed ID:24981151

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations