Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses


Wimmer, Timea; Erdelt, Kurt-Jürgen; Eichberger, Marlis; Roos, Malgorzata; Edelhoff, Daniel; Stawarczyk, Bogna (2014). Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dental Materials Journal, 33(6):717-724.

Abstract

This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively cemented on a polymeric model and on a base metal alloy one. For the fracture load test the FDPs were loaded at the centre of the pontic (1 mm/min). The data were analyzed using descriptive statistics, two- and one-way ANOVA followed by post-hoc Scheffé test and Weibull statistics. Fracture loads were found to be affected by the choice of materials used for the abutment models. The fracture load for zirconia FDPs cemented on metal abutments was higher than on polymeric abutment group. In contrast, Telio CAD cemented on polymeric abutments presented higher fracture loads than group on base metal alloy support.

This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively cemented on a polymeric model and on a base metal alloy one. For the fracture load test the FDPs were loaded at the centre of the pontic (1 mm/min). The data were analyzed using descriptive statistics, two- and one-way ANOVA followed by post-hoc Scheffé test and Weibull statistics. Fracture loads were found to be affected by the choice of materials used for the abutment models. The fracture load for zirconia FDPs cemented on metal abutments was higher than on polymeric abutment group. In contrast, Telio CAD cemented on polymeric abutments presented higher fracture loads than group on base metal alloy support.

Citations

1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 14 Jan 2015
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2014
Deposited On:14 Jan 2015 10:04
Last Modified:05 Apr 2016 18:48
Publisher:Japanese Society for Dental Materials and Devices
ISSN:0287-4547
Publisher DOI:https://doi.org/10.4012/dmj.2013-344
Permanent URL: https://doi.org/10.5167/uzh-104717

Download

[img]
Content: Published Version
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations