UZH-Logo

Maintenance Infos

Influence of PEEK surface modification on surface properties and bond strength to veneering resin composites


Keul, Christine; Liebermann, Anja; Schmidlin, Patrick R; Roos, Malgorzata; Sener, Beatrice; Stawarczyk, Bogna (2014). Influence of PEEK surface modification on surface properties and bond strength to veneering resin composites. Journal of Adhesive Dentistry, 16(4):383-392.

Abstract

PURPOSE: To test the impact of mechanical and chemical treatments of PEEK on surface roughness (SR), surface free energy (SFE), and tensile bond strength (TBS) to veneering resin composites.
MATERIALS AND METHODS: PEEK specimens (N = 680) were fabricated and divided into treatment groups (n = 170/group): 1. air abrasion (AIA); 2. etching with piranha solution (PIS); 3. air abrasion + piranha acid etching (AIP); and 4. no treatment (NO). Ten specimens of each treatment group were assessed with a contact angle measuring device and profilometer to determine SFE and SR, respectively. The remaining 160 specimens of each group were divided into subgroups according to coupling method (n = 32/subgroup): 1. Monobond Plus/ Heliobond (MH); 2. Visio.link (VL); 3. Clearfil Ceramic Primer (CCP); 4. Signum PEEK Bond (SPB); and 5. control, no coupling (CG). Specimens were veneered using Signum Composite/SiCo or Signum Ceramis/SiCe (both: n = 16), incubated in water (60 days at 37°C) and thermocycled (5000 cycles of 5°C/55°C). TBS was measured and data analyzed by three- and one-way ANOVA, Kruskal-Wallis and Mann-Whitney tests (p < 0.05).
RESULTS: A significant effect of surface treatment (p < 0.001) and coupling agent application (p < 0.001) on TBS was observed. AIA specimens with/without PIS showed the highest SFE, SR, and TBS. No differences were measured between PIS and NO, and between AIA and AIP. When no coupling agent was used, no adhesion was obtained. CCP resulted in low adhesion values, whereas MH, SPB, and VL exhibited increased TBS. No significant impact of the veneering resin composite on TBS was found (p = 0.424).
CONCLUSION: AIA and AIP combined with VL, SPB, and MH can be recommended for clinical use.

Abstract

PURPOSE: To test the impact of mechanical and chemical treatments of PEEK on surface roughness (SR), surface free energy (SFE), and tensile bond strength (TBS) to veneering resin composites.
MATERIALS AND METHODS: PEEK specimens (N = 680) were fabricated and divided into treatment groups (n = 170/group): 1. air abrasion (AIA); 2. etching with piranha solution (PIS); 3. air abrasion + piranha acid etching (AIP); and 4. no treatment (NO). Ten specimens of each treatment group were assessed with a contact angle measuring device and profilometer to determine SFE and SR, respectively. The remaining 160 specimens of each group were divided into subgroups according to coupling method (n = 32/subgroup): 1. Monobond Plus/ Heliobond (MH); 2. Visio.link (VL); 3. Clearfil Ceramic Primer (CCP); 4. Signum PEEK Bond (SPB); and 5. control, no coupling (CG). Specimens were veneered using Signum Composite/SiCo or Signum Ceramis/SiCe (both: n = 16), incubated in water (60 days at 37°C) and thermocycled (5000 cycles of 5°C/55°C). TBS was measured and data analyzed by three- and one-way ANOVA, Kruskal-Wallis and Mann-Whitney tests (p < 0.05).
RESULTS: A significant effect of surface treatment (p < 0.001) and coupling agent application (p < 0.001) on TBS was observed. AIA specimens with/without PIS showed the highest SFE, SR, and TBS. No differences were measured between PIS and NO, and between AIA and AIP. When no coupling agent was used, no adhesion was obtained. CCP resulted in low adhesion values, whereas MH, SPB, and VL exhibited increased TBS. No significant impact of the veneering resin composite on TBS was found (p = 0.424).
CONCLUSION: AIA and AIP combined with VL, SPB, and MH can be recommended for clinical use.

Citations

4 citations in Web of Science®
2 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 14 Jan 2015
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2014
Deposited On:14 Jan 2015 09:15
Last Modified:05 Apr 2016 18:48
Publisher:Quintessence Publishing
ISSN:1461-5185
Publisher DOI:https://doi.org/10.3290/j.jad.a32570
PubMed ID:25133270

Download

[img]
Content: Published Version
Filetype: PDF - Registered users only
Size: 330kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations