UZH-Logo

Maintenance Infos

Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement


Andreas, Martin; Wallner, Stephanie; Ruetzler, Kurt; Wiedemann, Dominik; Ehrlich, Marek; Heinze, Georg; Binder, Thomas; Moritz, Anton; Hiesmayr, Michael J; Kocher, Alfred; Laufer, Guenther (2015). Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement. European Journal of Cardio-Thoracic Surgery, 48(4):557-561.

Abstract

OBJECTIVES: Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre.
METHODS: All consecutive patients undergoing isolated aortic valve replacement with either a Carpentier-Edwards Magna pericardial prosthesis or a Medtronic Mosaic porcine prosthesis between 2002 and 2008 were analysed regarding preoperative characteristics, short- and long-term survival, valve-related complications and echocardiographic findings.
RESULTS: The Medtronic Mosaic was implanted in 163 patients and the Carpentier-Edwards Magna in 295 patients. The sizes of implanted valves were 22.4 ± 1.5 mm for the Mosaic and 21.8 ± 1.8 mm for the Magna (P = 0.001). The long-term survival rate was 76 and 56% after 5 and 10 years for the Medtronic Mosaic, which was comparable with the Carpentier-Edwards Magna (77 and 57%; P = 0.92). Overall long-term survival was comparable with an age- and sex-matched Austrian general population for both groups. Valve-related adverse events were similar between groups. The postoperative mean transvalvular gradient was significantly increased in the Mosaic group (24 ± 9 mmHg vs 17 ± 7 mmHg; P < 0.001).
CONCLUSIONS: Both types of aortic bioprostheses offer excellent results after isolated aortic valve replacement. Despite relevant differences in gradients, long-term survival was comparable with the expected normal survival for both bioprostheses. Patients with a porcine heart valve had a higher postoperative transvalvular gradient.

OBJECTIVES: Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre.
METHODS: All consecutive patients undergoing isolated aortic valve replacement with either a Carpentier-Edwards Magna pericardial prosthesis or a Medtronic Mosaic porcine prosthesis between 2002 and 2008 were analysed regarding preoperative characteristics, short- and long-term survival, valve-related complications and echocardiographic findings.
RESULTS: The Medtronic Mosaic was implanted in 163 patients and the Carpentier-Edwards Magna in 295 patients. The sizes of implanted valves were 22.4 ± 1.5 mm for the Mosaic and 21.8 ± 1.8 mm for the Magna (P = 0.001). The long-term survival rate was 76 and 56% after 5 and 10 years for the Medtronic Mosaic, which was comparable with the Carpentier-Edwards Magna (77 and 57%; P = 0.92). Overall long-term survival was comparable with an age- and sex-matched Austrian general population for both groups. Valve-related adverse events were similar between groups. The postoperative mean transvalvular gradient was significantly increased in the Mosaic group (24 ± 9 mmHg vs 17 ± 7 mmHg; P < 0.001).
CONCLUSIONS: Both types of aortic bioprostheses offer excellent results after isolated aortic valve replacement. Despite relevant differences in gradients, long-term survival was comparable with the expected normal survival for both bioprostheses. Patients with a porcine heart valve had a higher postoperative transvalvular gradient.

Citations

3 citations in Web of Science®
2 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

14 downloads since deposited on 18 Feb 2015
12 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Institute of Anesthesiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2015
Deposited On:18 Feb 2015 14:50
Last Modified:05 Apr 2016 18:54
Publisher:Oxford University Press
ISSN:1010-7940
Additional Information:This is a pre-copy-editing, author-produced PDF of an article accepted for publication in European Journal Cardio-Thoracic Surgery following peer review. The definitive publisher-authenticated version [Eur J Cardiothorac Surg (2014) doi: 10.1093/ejcts/ezu466] is available online at: http://ejcts.oxfordjournals.org/content/early/2014/12/18/ejcts.ezu466.
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/ejcts/ezu466
PubMed ID:25527170
Permanent URL: https://doi.org/10.5167/uzh-106121

Download

[img]
Preview
Content: Accepted Version
Filetype: PDF
Size: 105kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.