AIMS: The optimal implantable cardioverter defibrillator (ICD) system implant technique has not yet been defined in young patients and those with congenital heart disease (CHD). We describe our 5-year experience with epicardial pacing/sensing leads secured on the left cardiac chambers and a pleural defibrillation lead insertion along the third intercostal space. METHODS AND RESULTS: Implantable cardioverter defibrillator systems were implanted in 15 children and adolescents (age: 2.9-20.0 years) for primary (n = 11) or secondary (n = 4) prevention. Underlying CHD were hypertrophic (n = 10) or dilative cardiomyopathies (n = 2), primary electrical diseases (n = 2), and transposition of the great arteries (n = 1). Devices were placed in the rectus sheath (n = 5), or within the diaphragm (n = 10). Median defibrillation threshold at implant was 15 J (range: 10-25). During 5 years of follow-up (median: 22 months), nine appropriate and two inappropriate ICD discharges occurred. Four system revisions were required due to device recall, pleural lead dislodgement, epicardial lead fracture, and insulation break. Twelve months after the implantation, defibrillation threshold testing demonstrated stable thresholds of <or=20 J in five patients. CONCLUSION: Our 5-year experience demonstrates the efficacy of epicardial and pleural lead ICD systems. Inappropriate shocks and lead failures are observed as in other ICD systems. It represents an alternative implant technique for young and active patients and those without venous access.

Abstract

AIMS: The optimal implantable cardioverter defibrillator (ICD) system implant technique has not yet been defined in young patients and those with congenital heart disease (CHD). We describe our 5-year experience with epicardial pacing/sensing leads secured on the left cardiac chambers and a pleural defibrillation lead insertion along the third intercostal space. METHODS AND RESULTS: Implantable cardioverter defibrillator systems were implanted in 15 children and adolescents (age: 2.9-20.0 years) for primary (n = 11) or secondary (n = 4) prevention. Underlying CHD were hypertrophic (n = 10) or dilative cardiomyopathies (n = 2), primary electrical diseases (n = 2), and transposition of the great arteries (n = 1). Devices were placed in the rectus sheath (n = 5), or within the diaphragm (n = 10). Median defibrillation threshold at implant was 15 J (range: 10-25). During 5 years of follow-up (median: 22 months), nine appropriate and two inappropriate ICD discharges occurred. Four system revisions were required due to device recall, pleural lead dislodgement, epicardial lead fracture, and insulation break. Twelve months after the implantation, defibrillation threshold testing demonstrated stable thresholds of <or=20 J in five patients. CONCLUSION: Our 5-year experience demonstrates the efficacy of epicardial and pleural lead ICD systems. Inappropriate shocks and lead failures are observed as in other ICD systems. It represents an alternative implant technique for young and active patients and those without venous access.

Citations

10 citations in Web of Science®
13 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

3 downloads since deposited on 28 Jan 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2008
Deposited On:28 Jan 2009 14:02
Last Modified:05 Apr 2016 12:54
Publisher:Oxford University Press
ISSN:1099-5129
Publisher DOI:https://doi.org/10.1093/europace/eun214
PubMed ID:18701602

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations