Gorcsan, John; Sogaard, Peter; Bax, Jeroen J; Singh, Jagmeet P; Abraham, William T; Borer, Jeffrey S; Dickstein, Kenneth; Gras, Daniel; Krum, Henry; Brugada, Josep; Robertson, Michele; Ford, Ian; Holzmeister, Johannes; Ruschitzka, Frank (2016). Association of persistent or worsened echocardiographic dyssynchrony with unfavourable clinical outcomes in heart failure patients with narrow QRS width: a subgroup analysis of the EchoCRT trial. European Heart Journal, 37(1):49-59.

Abstract

AIMS EchoCRT was a randomized trial of cardiac resynchronization therapy (CRT) in severely symptomatic heart failure (HF) patients with narrow QRS width <130 ms, ejection fraction ≤35%, and echocardiographic dyssynchrony. All received CRT implants which were then randomized to CRT-On or CRT-Off. While the trial showed no benefit of CRT to these patients, the aim of this subgroup analysis was to test the hypothesis that persistent or worsening dyssynchrony is associated with unfavourable clinical outcomes. METHODS AND RESULTS We studied 614 EchoCRT patients with baseline and 6-month echocardiograms. Baseline dyssynchrony required for study inclusion was either tissue Doppler imaging longitudinal velocity delay ≥80 ms or speckle-tracking radial strain delay ≥130 ms. Persistent dyssynchrony at 6 months was observed similarly in both groups (77% in CRT-On; 76% in CRT-Off). Persistent dyssynchrony was associated with a significantly higher primary end point of death or HF hospitalization (HR = 1.54, 95% CI 1.03-2.30, P = 0.03), and in particular secondary endpoint of HF hospitalization (HR = 1.66, 95% CI 1.07-2.57, P = 0.02). HF hospitalizations were also associated with worsening longitudinal dyssynchrony (HR = 1.45, 95% CI 1.02-2.05, P = 0.037), and worsening radial dyssynchrony (HR = 1.81, 95% CI 1.16-2.81, P = 0.008). Associations of persistent or worsening dyssynchrony with outcomes were similar in CRT-Off and CRT-On groups. CONCLUSIONS Persistent or worsening echocardiographic dyssynchrony in HF patients with narrow QRS width was a marker for unfavourable clinical outcomes unaffected by CRT. In particular, echocardiographic dyssynchrony on follow-up was strongly associated with HF hospitalizations and appears to be a prognostic marker of disease severity.

Abstract

AIMS EchoCRT was a randomized trial of cardiac resynchronization therapy (CRT) in severely symptomatic heart failure (HF) patients with narrow QRS width <130 ms, ejection fraction ≤35%, and echocardiographic dyssynchrony. All received CRT implants which were then randomized to CRT-On or CRT-Off. While the trial showed no benefit of CRT to these patients, the aim of this subgroup analysis was to test the hypothesis that persistent or worsening dyssynchrony is associated with unfavourable clinical outcomes. METHODS AND RESULTS We studied 614 EchoCRT patients with baseline and 6-month echocardiograms. Baseline dyssynchrony required for study inclusion was either tissue Doppler imaging longitudinal velocity delay ≥80 ms or speckle-tracking radial strain delay ≥130 ms. Persistent dyssynchrony at 6 months was observed similarly in both groups (77% in CRT-On; 76% in CRT-Off). Persistent dyssynchrony was associated with a significantly higher primary end point of death or HF hospitalization (HR = 1.54, 95% CI 1.03-2.30, P = 0.03), and in particular secondary endpoint of HF hospitalization (HR = 1.66, 95% CI 1.07-2.57, P = 0.02). HF hospitalizations were also associated with worsening longitudinal dyssynchrony (HR = 1.45, 95% CI 1.02-2.05, P = 0.037), and worsening radial dyssynchrony (HR = 1.81, 95% CI 1.16-2.81, P = 0.008). Associations of persistent or worsening dyssynchrony with outcomes were similar in CRT-Off and CRT-On groups. CONCLUSIONS Persistent or worsening echocardiographic dyssynchrony in HF patients with narrow QRS width was a marker for unfavourable clinical outcomes unaffected by CRT. In particular, echocardiographic dyssynchrony on follow-up was strongly associated with HF hospitalizations and appears to be a prognostic marker of disease severity.

Citations

5 citations in Web of Science®
6 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:1 January 2016
Deposited On:18 Feb 2016 11:22
Last Modified:05 Apr 2016 20:02
Publisher:Oxford University Press
ISSN:0195-668X
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/eurheartj/ehv418
PubMed ID:26321238

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations