UZH-Logo

Maintenance Infos

Ankh in the depth – Subdermal 3D art implants: Radiological identification with body modification


Schaerli, Sarah; Berger, Florian; Thali, Michael J; Gascho, Dominic (2016). Ankh in the depth – Subdermal 3D art implants: Radiological identification with body modification. Legal Medicine, 20:12-14.

Abstract

One of the core tasks in forensic medico-legal investigations is the identification of the deceased. Radiological identification using postmortem computed tomography (PMCT) is a powerful technique. In general, the implementation of forensic PMCT is rising worldwide. In addition to specific anatomical structures, medical implants or prostheses serve as markers for the comparison of antemortem and postmortem images to identify the deceased. However, non-medical implants, such as subdermal three-dimensional (3D) art implants, also allow for radiological identification. These implants are a type of body modification that have become increasingly popular over the last several decades and will therefore be employed more frequently in radiological identification in the future. To the best of our knowledge, this is the first case of radiological identification with a subdermal 3D art implant. Further, the present case shows the characteristics of a silicone 3D art implant on computed tomography, magnetic resonance imaging and X-rays.

Abstract

One of the core tasks in forensic medico-legal investigations is the identification of the deceased. Radiological identification using postmortem computed tomography (PMCT) is a powerful technique. In general, the implementation of forensic PMCT is rising worldwide. In addition to specific anatomical structures, medical implants or prostheses serve as markers for the comparison of antemortem and postmortem images to identify the deceased. However, non-medical implants, such as subdermal three-dimensional (3D) art implants, also allow for radiological identification. These implants are a type of body modification that have become increasingly popular over the last several decades and will therefore be employed more frequently in radiological identification in the future. To the best of our knowledge, this is the first case of radiological identification with a subdermal 3D art implant. Further, the present case shows the characteristics of a silicone 3D art implant on computed tomography, magnetic resonance imaging and X-rays.

Altmetrics

Downloads

0 downloads since deposited on 03 May 2016
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Legal Medicine
Dewey Decimal Classification:340 Law
610 Medicine & health
Uncontrolled Keywords:Radiological identification; 3D art implants; Body modification; PMCT; Postmortem imaging; Ankh
Language:English
Date:May 2016
Deposited On:03 May 2016 15:18
Last Modified:04 May 2016 08:12
Publisher:Elsevier
ISSN:1344-6223
Publisher DOI:https://doi.org/10.1016/j.legalmed.2016.03.001

Download

[img]
Content: Published Version
Language: English
Filetype: PDF - Registered users only
Size: 878kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations