Do hardware artefacts influence the performance of head and neck PET scans in patients with oral cavity squamous cell cancer?


Goerres, G W; Schmid, D T; Eyrich, G K (2003). Do hardware artefacts influence the performance of head and neck PET scans in patients with oral cavity squamous cell cancer? Dentomaxillofacial Radiology, 32(6):365-371.

Abstract

OBJECTIVE: The purpose of this study was to evaluate the influence of (68)Ge-based and CT-based attenuation correction as well as two standard image reconstruction algorithms on the appearance of artefacts due to dental hardware. Additionally, the intensity of such artefacts was compared with (18)F-fluorodeoxyglucose (FDG) uptake in patients with known oral cavity squamous cell cancer. METHODS: Thirty-two metallic and non-metallic objects used for dentistry/dental surgery were scanned in a water-bath filled with FDG on a combined PET/CT scanner. Images were reconstructed with either CT-based or (68)Ge-based transmission data and by using iterative reconstruction or filtered backprojection. The intensity of artefacts was assessed visually using a subjective scale from 0 (no artefact visible) to 4 (very strong artefact), and by quantitative measurements. In a second study, images of 30 patients with known squamous cell cancer and dental hardware were retrospectively analysed by two observers, again using a visual assessment grading system. Wilcoxon signed rank test was used for statistical comparisons. RESULTS: Eighteen of 32 objects caused artefacts, which were visible with both attenuation correction methods. CT-based attenuation correction was visually more intense than (68)Ge-based attenuation correction (P<0.0001), and the measured (18)F concentration was also higher (P=0.0002). No difference was found between the reconstruction algorithms. In 28 of 30 patients the primary tumour was visible. FDG uptake in the primary tumour was significantly higher than measured (18)F concentration in artefacts (P<0.0001). CONCLUSION: Attenuation correction of PET images generates artefacts adjacent to dental hardware that mimic FDG uptake. In this series, the primary lesion was discriminated from artefacts.

OBJECTIVE: The purpose of this study was to evaluate the influence of (68)Ge-based and CT-based attenuation correction as well as two standard image reconstruction algorithms on the appearance of artefacts due to dental hardware. Additionally, the intensity of such artefacts was compared with (18)F-fluorodeoxyglucose (FDG) uptake in patients with known oral cavity squamous cell cancer. METHODS: Thirty-two metallic and non-metallic objects used for dentistry/dental surgery were scanned in a water-bath filled with FDG on a combined PET/CT scanner. Images were reconstructed with either CT-based or (68)Ge-based transmission data and by using iterative reconstruction or filtered backprojection. The intensity of artefacts was assessed visually using a subjective scale from 0 (no artefact visible) to 4 (very strong artefact), and by quantitative measurements. In a second study, images of 30 patients with known squamous cell cancer and dental hardware were retrospectively analysed by two observers, again using a visual assessment grading system. Wilcoxon signed rank test was used for statistical comparisons. RESULTS: Eighteen of 32 objects caused artefacts, which were visible with both attenuation correction methods. CT-based attenuation correction was visually more intense than (68)Ge-based attenuation correction (P<0.0001), and the measured (18)F concentration was also higher (P=0.0002). No difference was found between the reconstruction algorithms. In 28 of 30 patients the primary tumour was visible. FDG uptake in the primary tumour was significantly higher than measured (18)F concentration in artefacts (P<0.0001). CONCLUSION: Attenuation correction of PET images generates artefacts adjacent to dental hardware that mimic FDG uptake. In this series, the primary lesion was discriminated from artefacts.

Citations

19 citations in Web of Science®
28 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Cranio-Maxillofacial Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:1 November 2003
Deposited On:11 Feb 2008 12:23
Last Modified:05 Apr 2016 12:19
Publisher:British Institute of Radiology
ISSN:0250-832X
Publisher DOI:10.1259/dmfr/77741718
PubMed ID:15070838

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations