Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography


Willmann, J K; Wildermuth, S; Pfammatter, T; Roos, J E; Seifert, Burkhardt; Hilfiker, P R; Marincek, B; Weishaupt, D (2003). Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography. Radiology, 226(3):798-811.

Abstract

PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.

PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.

Citations

99 citations in Web of Science®
145 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 29 Jun 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2003
Deposited On:29 Jun 2009 14:07
Last Modified:05 Apr 2016 13:16
Publisher:Radiological Society of North America
ISSN:0033-8419
Publisher DOI:https://doi.org/10.1148/radiol.2271020014
PubMed ID:12601190
Permanent URL: https://doi.org/10.5167/uzh-19454

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations