UZH-Logo

Maintenance Infos

Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability


Keller, T M; Rake, A; Michel, S C A; Seifert, Burkhardt; Efe, G; Treiber, K; Huch, R; Marincek, B; Kubik-Huch, R A (2003). Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability. Radiology, 227(1):37-43.

Abstract

PURPOSE: To establish obstetric magnetic resonance (MR) pelvimetric reference values in a large study population and stratify them according to delivery modality and to determine the intra- and interobserver error and intraindividual variability of MR pelvimetric assessment in volunteers. MATERIALS AND METHODS: MR pelvimetric data were retrospectively reviewed in 781 women (mean age, 28.9 years +/- 5.2 [SD]) clinically referred, and the data were correlated to obstetric history to derive normative values. Five observers assessed results of multiple MR pelvimetric examinations in 10 female volunteers (mean age, 34.7 years +/- 6.0; eight nullipara, two primipara) to provide data for measurement error analysis. RESULTS: All values were higher in the spontaneous vaginal delivery subgroup (n = 100) and lower in the cesarean section or vacuum extraction subgroup (n = 130; intersubgroup difference, P <.001, Mann-Whitney U test). Pelvimetric parameters in the group undergoing spontaneous vaginal delivery were as follows: obstetric conjugate, 121.7 mm +/- 8.6; interspinous distance, 112.3 mm +/- 7.9; intertuberous distance, 120.6 mm +/- 11.3; transverse diameter, 129.5 mm +/- 8.7; and sagittal outlet, 115.8 mm +/- 9.9. In the volunteer study, intraobserver, interobserver, and intraindividual reliabilities were high for the obstetric conjugate (0.94-0.96), interspinous distance (0.92-0.95), and transverse diameter (0.95-0.98) but low for intertuberous distance (0.64-0.87) and sagittal outlet (0.66-0.85). CONCLUSION: Pelvimetric dimensions are smaller in women undergoing cesarean section or vacuum extraction than they are in those delivering vaginally. The pelvimetric parameters associated with the largest measurement errors are intertuberous distance and sagittal outlet.

PURPOSE: To establish obstetric magnetic resonance (MR) pelvimetric reference values in a large study population and stratify them according to delivery modality and to determine the intra- and interobserver error and intraindividual variability of MR pelvimetric assessment in volunteers. MATERIALS AND METHODS: MR pelvimetric data were retrospectively reviewed in 781 women (mean age, 28.9 years +/- 5.2 [SD]) clinically referred, and the data were correlated to obstetric history to derive normative values. Five observers assessed results of multiple MR pelvimetric examinations in 10 female volunteers (mean age, 34.7 years +/- 6.0; eight nullipara, two primipara) to provide data for measurement error analysis. RESULTS: All values were higher in the spontaneous vaginal delivery subgroup (n = 100) and lower in the cesarean section or vacuum extraction subgroup (n = 130; intersubgroup difference, P <.001, Mann-Whitney U test). Pelvimetric parameters in the group undergoing spontaneous vaginal delivery were as follows: obstetric conjugate, 121.7 mm +/- 8.6; interspinous distance, 112.3 mm +/- 7.9; intertuberous distance, 120.6 mm +/- 11.3; transverse diameter, 129.5 mm +/- 8.7; and sagittal outlet, 115.8 mm +/- 9.9. In the volunteer study, intraobserver, interobserver, and intraindividual reliabilities were high for the obstetric conjugate (0.94-0.96), interspinous distance (0.92-0.95), and transverse diameter (0.95-0.98) but low for intertuberous distance (0.64-0.87) and sagittal outlet (0.66-0.85). CONCLUSION: Pelvimetric dimensions are smaller in women undergoing cesarean section or vacuum extraction than they are in those delivering vaginally. The pelvimetric parameters associated with the largest measurement errors are intertuberous distance and sagittal outlet.

Citations

18 citations in Web of Science®
25 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 29 Jun 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2003
Deposited On:29 Jun 2009 12:35
Last Modified:05 Apr 2016 13:16
Publisher:Radiological Society of North America
ISSN:0033-8419
Publisher DOI:https://doi.org/10.1148/radiol.2271011658
PubMed ID:12601187
Permanent URL: https://doi.org/10.5167/uzh-19455

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations