Friction between finger flexor tendons and the pulley system in the crimp grip position


Moor, B K; Nagy, L; Snedeker, J G; Schweizer, A (2009). Friction between finger flexor tendons and the pulley system in the crimp grip position. Clinical Biomechanics, 24(1):20-25.

Abstract

BACKGROUND: Disruption of the finger flexor tendon pulleys are the most often occurring injury in rock climbers due to bowstringing of tendons during crimp grip position. The aim of this study was to quantify friction between the flexor tendons and pulleys and the influence of high load and speed of movement as a potential factor of pulley disruption. METHODS: Friction between the flexor tendons and pulleys of eight human cadaver fingers was indirectly determined using an isokinetic movement device. During flexion and extension movement with rotational speed from 30 to 210 deg/s in the proximal interphalangeal joint and with load from 20 to 100 N to the flexor tendons the flexion force at the tip of the finger was measured. FINDINGS: With 40 N loaded flexor tendons the force at the fingertip was 14.5 N (SD1.5) during extension and 12.6N (SD1.3) during flexion movement. Corresponding force difference of 12.9% and 3.77 N (SD0.6) force of friction can be calculated. Friction peaked at 85.8 degrees (SD2.05) of flexion of the proximal interphalangeal joint. Different speed of motion and load to the flexor tendons did not influence force difference other than linear. INTERPRETATION: Considerable friction between flexor tendons and pulleys is apparent and therefore may have an influence on pulley injuries. Particularly during the crimp grip position where the proximal interphalangeal joint is flexed about 90 degrees shows the greatest amount of friction. However there was no change of friction during high speed motion and no other than linear increase during high load.

Abstract

BACKGROUND: Disruption of the finger flexor tendon pulleys are the most often occurring injury in rock climbers due to bowstringing of tendons during crimp grip position. The aim of this study was to quantify friction between the flexor tendons and pulleys and the influence of high load and speed of movement as a potential factor of pulley disruption. METHODS: Friction between the flexor tendons and pulleys of eight human cadaver fingers was indirectly determined using an isokinetic movement device. During flexion and extension movement with rotational speed from 30 to 210 deg/s in the proximal interphalangeal joint and with load from 20 to 100 N to the flexor tendons the flexion force at the tip of the finger was measured. FINDINGS: With 40 N loaded flexor tendons the force at the fingertip was 14.5 N (SD1.5) during extension and 12.6N (SD1.3) during flexion movement. Corresponding force difference of 12.9% and 3.77 N (SD0.6) force of friction can be calculated. Friction peaked at 85.8 degrees (SD2.05) of flexion of the proximal interphalangeal joint. Different speed of motion and load to the flexor tendons did not influence force difference other than linear. INTERPRETATION: Considerable friction between flexor tendons and pulleys is apparent and therefore may have an influence on pulley injuries. Particularly during the crimp grip position where the proximal interphalangeal joint is flexed about 90 degrees shows the greatest amount of friction. However there was no change of friction during high speed motion and no other than linear increase during high load.

Citations

8 citations in Web of Science®
8 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 16 Nov 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:January 2009
Deposited On:16 Nov 2009 14:01
Last Modified:05 Apr 2016 13:30
Publisher:Elsevier
ISSN:0268-0033
Publisher DOI:https://doi.org/10.1016/j.clinbiomech.2008.10.002
PubMed ID:19041166

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations