Mechanically adjustable coil array for wrist MRI


Nordmeyer-Massner, J A; De Zanche, N; Pruessmann, K P (2009). Mechanically adjustable coil array for wrist MRI. Magnetic Resonance in Medicine, 61(2):429-438.

Abstract

In this work, the concept of mechanically adjustable MR receiver coil arrays is proposed and implemented for the specific case of human wrist imaging. An eight-channel wrist array for proton MRI at 3 Tesla was constructed and evaluated. The array adjusts to the individual anatomy by a mechanism that fits a configuration of flexible coil elements closely around the wrist. With such adjustability, it is challenging to ensure robust electrical behavior and signal-to-noise (SNR) performance. These requirements are met by preamplifier decoupling and a suitable matching strategy based on pi networks that render the coil responses robust against changes in tuning, loading and mutual coupling. The robustness of the resulting SNR yield was studied by varying the effective coil matching over a wide range in a phantom imaging experiment. While SNR variation of up to 25% was observed at the surface of the phantom the SNR was essentially constant in the critical center region. A second SNR study in wrist phantoms of different sizes confirmed the benefits of bringing the coil elements very close, up to 3 mm, to the individual target volume. These findings were supported by initial in vivo imaging, exploiting high-sensitivity detection for highly resolved structural imaging. Copyright 2009 Wiley-Liss, Inc.

In this work, the concept of mechanically adjustable MR receiver coil arrays is proposed and implemented for the specific case of human wrist imaging. An eight-channel wrist array for proton MRI at 3 Tesla was constructed and evaluated. The array adjusts to the individual anatomy by a mechanism that fits a configuration of flexible coil elements closely around the wrist. With such adjustability, it is challenging to ensure robust electrical behavior and signal-to-noise (SNR) performance. These requirements are met by preamplifier decoupling and a suitable matching strategy based on pi networks that render the coil responses robust against changes in tuning, loading and mutual coupling. The robustness of the resulting SNR yield was studied by varying the effective coil matching over a wide range in a phantom imaging experiment. While SNR variation of up to 25% was observed at the surface of the phantom the SNR was essentially constant in the critical center region. A second SNR study in wrist phantoms of different sizes confirmed the benefits of bringing the coil elements very close, up to 3 mm, to the individual target volume. These findings were supported by initial in vivo imaging, exploiting high-sensitivity detection for highly resolved structural imaging. Copyright 2009 Wiley-Liss, Inc.

Citations

7 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 24 Nov 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2009
Deposited On:24 Nov 2009 10:35
Last Modified:05 Apr 2016 13:33
Publisher:Wiley-Blackwell
ISSN:0740-3194
Publisher DOI:10.1002/mrm.21868
PubMed ID:19161134
Permanent URL: http://doi.org/10.5167/uzh-24015

Download

[img]Filetype: PDF - Registered users only
Size: 2MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations