Schneider, P; Voide, R; Stampanoni, M; Müller, R (2009). Post-processing technique for improved assessment of hard tissues in the submicrometer domain using local synchrotron radiation-based computed tomography. Biomedizinische Technik. Biomedical Engineering, 54(1):48-54.
Full text not available from this repository.
Abstract
During the last two decades micro-computed tomography has become the method of choice for the non-destructive assessment and quantitative morphometry of hard tissues in three dimensions. With the advent of third-generation synchrotron radiation sources, micro-computed tomography in the micrometer range has become feasible and has been employed to analyze local bone tissue properties. However, owing to limitations regarding the tradeoff between object size and spatial resolution, non-destructive conventional global computed tomography of hard tissues, such as bone, remains unachievable in the submicrometer domain so far. Here, we report on a post-processing technique for the assessment of hard tissues using local synchrotron radiation-based computed tomography, which overcomes this experimental limitation.
| Item Type: | Journal Article, refereed, original work |
|---|---|
| Communities & Collections: | 04 Faculty of Medicine > Institute of Biomedical Engineering |
| DDC: | 170 Ethics 610 Medicine & health |
| Date: | 2009 |
| Deposited On: | 03 Feb 2010 15:14 |
| Last Modified: | 04 Apr 2012 15:06 |
| Publisher: | De Gruyter |
| ISSN: | 0013-5585 |
| Publisher DOI: | 10.1515/BMT.2009.007 |
| PubMed ID: | 19182873 |