Quick Search:

uzh logo
Browse by:
bullet
bullet
bullet
bullet

Zurich Open Repository and Archive

Permanent URL to this publication: http://dx.doi.org/10.5167/uzh-27194

Valenta, I; Treyer, V; Husmann, L; Gaemperli, O; Schindler, M J; Herzog, B A; Veit-Heibach, P; Buechel, R R; Nkoulou, R; Pazhenkottil, A P; Kaufmann, P A (2010). New reconstruction algorithm allows shortened acquisition time for myocardial perfusion SPECT. European Journal of Nuclear Medicine and Molecular Imaging, 37(4):750-757.

[img]
Preview
Accepted Version
PDF
1MB

View at publisher

Abstract

PURPOSE: Shortening scan time and/or reducing radiation dose at maintained image quality are the main issues of the current research in radionuclide myocardial perfusion imaging (MPI). We aimed to validate a new iterative reconstruction (IR) algorithm for SPECT MPI allowing shortened acquisition time (HALF time) while maintaining image quality vs. standard full time acquisition (FULL time). METHODS: In this study, 50 patients, referred for evaluation of known or suspected coronary artery disease by SPECT MPI using 99mTc-Tetrofosmin, underwent 1-day adenosine stress 300 MBq/rest 900 MBq protocol with standard (stress 15 min/rest 15 min FULL time) immediately followed by short emission scan (stress 9 min/rest 7 min HALF time) on a Ventri SPECT camera (GE Healthcare). FULL time scans were processed with IR, short scans were additionally processed with a recently developed software algorithm for HALF time emission scans. All reconstructions were subsequently analyzed using commercially available software (QPS/QGS, Cedars Medical Sinai) with/without X-ray based attenuation correction (AC). Uptake values (percent of maximum) were compared by regression and Bland-Altman (BA) analysis in a 20-segment model. RESULTS: HALF scans yielded a 96% readout and 100% clinical diagnosis concordance compared to FULL. Correlation for uptake in each segment (n = 1,000) was r = 0.87at stress (p < 0.001) and r = 0.89 at rest (p < 0.001) with respective BA limits of agreement of -11% to 10% and -12% to 11%. After AC similar correlation (r = 0.82, rest; r = 0.80, stress, both p < 0.001) and BA limits were found (-12% to 10%; -13% to 12%). CONCLUSION: With the new IR algorithm, SPECT MPI can be acquired at half of the scan time without compromising image quality, resulting in an excellent agreement with FULL time scans regarding to uptake and clinical conclusion.

Citations

20 citations in Web of Science®
25 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

68 downloads since deposited on 13 Jan 2010
12 downloads since 12 months

Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
04 Faculty of Medicine > Center for Integrative Human Physiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
DDC:570 Life sciences; biology
610 Medicine & health
Language:English
Date:2010
Deposited On:13 Jan 2010 13:18
Last Modified:27 Nov 2013 19:20
Publisher:Springer
ISSN:1619-7070
Additional Information:The original publication is available at www.springerlink.com
Publisher DOI:10.1007/s00259-009-1300-0
PubMed ID:19921186