Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns


Cömlekoglu, M; Dündar, M; Özcan, M; Güngör, M; Gokce, B; Artunc, C (2009). Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Operative Dentistry, 34(5):586-592.

Abstract

The current study evaluated the effect of different cervical finish line designs on the marginal adaptation of a zirconia ceramic. Four different marginal finish lines (c: chamfer, mc: mini-chamfer, fe: feather-edge and s: rounded shoulder) were prepared on phantom incisors. Die models for each preparation group (N = 28, n = 7 per finish line design group) were made of epoxy resin. Y-TZP (ICE Zirkon) frameworks were manufactured by a copy-milling system (Zirconzahn) using prefabricated blanks and tried on the master models for initial adaptation of the framework; they were then sintered, followed by veneering (Zirconzahn). The finished crowns were cemented with a polycarboxylate cement (Poly F) under 300 g load and ultrasonically cleaned. The specimens were sliced and the marginal gap was measured, considering absolute marginal opening (AMO) and marginal opening (MO) for each coping under a stereomicroscope with image processing software (Lucia). The measurements were statistically analyzed using the Kruskal Wallis, Mann Whitney and Wilcoxon Signed Ranks tests at a significance level of alpha = 0.01. Means of AMO measurement (microm) for the feather-edge finish line (87 +/- 10) was significantly lower than that of the chamfer (144 +/- 14), shoulder (114 +/- 16) and mini-chamfer finish line types (114 +/- 11) (p < 0.01). Means of MO measurements was the lowest for feather-edge finish line (68 +/- 9) (p < 0.01) and then, in ascending order, shoulder (95 +/- 9), mini-chamfer (97 +/- 12) and chamfer (128 +/- 10). The cervical finish line type had an influence on the marginal adaptation of the tested zirconia ceramic. Although the feather-edge finish line resulted in lower AMO and MO values, with its proven mechanical disadvantage, it cannot be recommended in clinical applications of zirconia crowns. This type of finish line has acted solely as a control group to test the null hypothesis in the current study. For better marginal adaptation, both shoulder and mini-chamfer finish line types could be suggested for zirconia crowns.

The current study evaluated the effect of different cervical finish line designs on the marginal adaptation of a zirconia ceramic. Four different marginal finish lines (c: chamfer, mc: mini-chamfer, fe: feather-edge and s: rounded shoulder) were prepared on phantom incisors. Die models for each preparation group (N = 28, n = 7 per finish line design group) were made of epoxy resin. Y-TZP (ICE Zirkon) frameworks were manufactured by a copy-milling system (Zirconzahn) using prefabricated blanks and tried on the master models for initial adaptation of the framework; they were then sintered, followed by veneering (Zirconzahn). The finished crowns were cemented with a polycarboxylate cement (Poly F) under 300 g load and ultrasonically cleaned. The specimens were sliced and the marginal gap was measured, considering absolute marginal opening (AMO) and marginal opening (MO) for each coping under a stereomicroscope with image processing software (Lucia). The measurements were statistically analyzed using the Kruskal Wallis, Mann Whitney and Wilcoxon Signed Ranks tests at a significance level of alpha = 0.01. Means of AMO measurement (microm) for the feather-edge finish line (87 +/- 10) was significantly lower than that of the chamfer (144 +/- 14), shoulder (114 +/- 16) and mini-chamfer finish line types (114 +/- 11) (p < 0.01). Means of MO measurements was the lowest for feather-edge finish line (68 +/- 9) (p < 0.01) and then, in ascending order, shoulder (95 +/- 9), mini-chamfer (97 +/- 12) and chamfer (128 +/- 10). The cervical finish line type had an influence on the marginal adaptation of the tested zirconia ceramic. Although the feather-edge finish line resulted in lower AMO and MO values, with its proven mechanical disadvantage, it cannot be recommended in clinical applications of zirconia crowns. This type of finish line has acted solely as a control group to test the null hypothesis in the current study. For better marginal adaptation, both shoulder and mini-chamfer finish line types could be suggested for zirconia crowns.

Citations

19 citations in Web of Science®
21 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

275 downloads since deposited on 12 Feb 2010
51 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2009
Deposited On:12 Feb 2010 08:26
Last Modified:05 Apr 2016 13:54
Publisher:Academy of Operative Dentistry
ISSN:0361-7734
Publisher DOI:https://doi.org/10.2341/08-076-L
Related URLs:http://www.jopdentonline.org (Publisher)
PubMed ID:19830974
Permanent URL: https://doi.org/10.5167/uzh-30477

Download

[img]
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher
[img]
Filetype: PDF - Registered users only
Size: 3MB

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations