UZH-Logo

Maintenance Infos

Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency


Goetti, R; Leschka, S; Baumüller, S; Plass, A; Wieser, M; Desbiolles, L; Stolzmann, P; Falk, V; Marincek, B; Alkadhi, H; Feuchtner, G (2010). Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency. Investigative Radiology, 45(6):324-330.

Abstract

OBJECTIVES:: To prospectively assess electrocardiography (ECG)-synchronized dual-source computed tomography (CT) in high-pitch spiral acquisition mode for the evaluation of coronary artery bypass graft (CABG) patency regarding image quality and radiation dose. MATERIALS AND METHODS:: Fifty consecutive patients (47 men, age 69.6 +/- 9.6 years, body mass index 26.6 +/- 3.5 kg/m) underwent clinically indicated 128-slice dual-source CT angiography of the entire thorax for the evaluation of graft patency after CABG surgery using a prospectively ECG-synchronized high-pitch spiral acquisition mode (pitch 3.2; 100 kV tube voltage, 0.28 seconds gantry rotation time). Heart rates (HR) were noted. Image quality of the proximal anastomosis, graft body, distal anastomosis, and postanastomotic coronary artery were graded by 2 independent readers on a 3-point scale (1 = excellent, 2 = moderate, and 3 = poor/nondiagnostic). Quantitative image quality parameters (noise, contrast-to-noise ratio) were measured. Effective radiation doses were calculated. RESULTS:: Mean HR was 76 +/- 19 bpm (range, 45-135 bpm). Median scan time was 0.9 seconds (range, 0.76-1.17 seconds), mean scan length was 349 +/- 38 mm (range, 294-452 mm). A total of 125 CABG (54% arterial grafts) and 465 vessel sections were analyzed. Twelve grafts were proximally occluded. Diagnostic image quality was obtained in 462 (99.4%) sections. Of those, image quality was excellent in 397 (85.4%) and moderate in 65 (14.0%). All 3 (0.6%) nondiagnostic sections affected the distal anastomosis due to motion artifacts caused by high HR. Separating the study population by the median HR of 71 bpm, image quality of the distal anastomosis regarding motion artifacts was significantly lower at high HR (P < 0.05). Interobserver agreement in grading image quality of graft segments was good (kappa = 0.77). Image noise in the aorta was 36.9 +/- 8.1, contrast-to-noise ratio was 13.1 +/- 4.2. Effective radiation dose was 2.3 +/- 0.3 mSv. CONCLUSIONS:: The patency of coronary artery bypass grafts can be assessed with decreasing image quality at high HR in high-pitch prospectively ECG-synchronized thoracic 128-slice dual-source CT angiography at a low radiation dose.

Abstract

OBJECTIVES:: To prospectively assess electrocardiography (ECG)-synchronized dual-source computed tomography (CT) in high-pitch spiral acquisition mode for the evaluation of coronary artery bypass graft (CABG) patency regarding image quality and radiation dose. MATERIALS AND METHODS:: Fifty consecutive patients (47 men, age 69.6 +/- 9.6 years, body mass index 26.6 +/- 3.5 kg/m) underwent clinically indicated 128-slice dual-source CT angiography of the entire thorax for the evaluation of graft patency after CABG surgery using a prospectively ECG-synchronized high-pitch spiral acquisition mode (pitch 3.2; 100 kV tube voltage, 0.28 seconds gantry rotation time). Heart rates (HR) were noted. Image quality of the proximal anastomosis, graft body, distal anastomosis, and postanastomotic coronary artery were graded by 2 independent readers on a 3-point scale (1 = excellent, 2 = moderate, and 3 = poor/nondiagnostic). Quantitative image quality parameters (noise, contrast-to-noise ratio) were measured. Effective radiation doses were calculated. RESULTS:: Mean HR was 76 +/- 19 bpm (range, 45-135 bpm). Median scan time was 0.9 seconds (range, 0.76-1.17 seconds), mean scan length was 349 +/- 38 mm (range, 294-452 mm). A total of 125 CABG (54% arterial grafts) and 465 vessel sections were analyzed. Twelve grafts were proximally occluded. Diagnostic image quality was obtained in 462 (99.4%) sections. Of those, image quality was excellent in 397 (85.4%) and moderate in 65 (14.0%). All 3 (0.6%) nondiagnostic sections affected the distal anastomosis due to motion artifacts caused by high HR. Separating the study population by the median HR of 71 bpm, image quality of the distal anastomosis regarding motion artifacts was significantly lower at high HR (P < 0.05). Interobserver agreement in grading image quality of graft segments was good (kappa = 0.77). Image noise in the aorta was 36.9 +/- 8.1, contrast-to-noise ratio was 13.1 +/- 4.2. Effective radiation dose was 2.3 +/- 0.3 mSv. CONCLUSIONS:: The patency of coronary artery bypass grafts can be assessed with decreasing image quality at high HR in high-pitch prospectively ECG-synchronized thoracic 128-slice dual-source CT angiography at a low radiation dose.

Citations

30 citations in Web of Science®
42 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2010
Deposited On:14 May 2010 14:43
Last Modified:05 Apr 2016 14:06
Publisher:Lippincott Wiliams & Wilkins
ISSN:0020-9996
Publisher DOI:https://doi.org/10.1097/RLI.0b013e3181dfa47e
PubMed ID:20404735

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations