UZH-Logo

Compartment pressure of the rectus sheath accurately reflects intra-abdominal pressure in a porcine model


Benninger, E; Laschke, M W; Cardell, M; Holstein, J H; Seifert, Burkhardt; Keel, M; Trentz, O; Menger, M D; Meier, C (2010). Compartment pressure of the rectus sheath accurately reflects intra-abdominal pressure in a porcine model. Journal of Surgical Research, 161(2):295-300.

Abstract

BACKGROUND: To investigate whether the compartment pressure of the rectus sheath (CPRS) reflects the intra-abdominal pressure (IAP) under various conditions of intra-abdominal hypertension (IAH) in a pig model. METHODS: Design: Prospective experimental study with in vivo pressure measurements. Setting: Institute for Clinical and Experimental Surgery, University of Saarland. Animals: Seven domestic male pigs (body weight 34.8+/-2.5 kg). Interventions: Stepwise increase and decrease of IAP by means of CO(2) pneumoperitoneum. Continuous direct measurement of the IAP and correspondent indirect IAP measurement techniques including analysis of intravesical pressure (IVP), femoral vein pressure (FVP), and CPRS. RESULTS: Bland-Altman analysis comparing direct IAP measurement with correspondent CPRS showed good agreement for IAP between 12 mm Hg and 30 mm Hg (bias -0.5 mm Hg, lower and upper limits of agreement (LLA/ULA) -3.5/2.5 mm Hg). FVP (bias -0.3 mm Hg, LLA/ULA -2.3/1.6 mm Hg) and IVP (bias 0.4 mm Hg, LLA/ULA -2.1/2.9 mm Hg) demonstrated similar results compared with direct IAP measurement. Agreement was worse for all indirect IAP measurement techniques for IAP<12 mm Hg. CONCLUSIONS: CPRS accurately reflects IAP for IAP> or =12 mm Hg. Accuracy is similar to established indirect IAP measurement techniques.

BACKGROUND: To investigate whether the compartment pressure of the rectus sheath (CPRS) reflects the intra-abdominal pressure (IAP) under various conditions of intra-abdominal hypertension (IAH) in a pig model. METHODS: Design: Prospective experimental study with in vivo pressure measurements. Setting: Institute for Clinical and Experimental Surgery, University of Saarland. Animals: Seven domestic male pigs (body weight 34.8+/-2.5 kg). Interventions: Stepwise increase and decrease of IAP by means of CO(2) pneumoperitoneum. Continuous direct measurement of the IAP and correspondent indirect IAP measurement techniques including analysis of intravesical pressure (IVP), femoral vein pressure (FVP), and CPRS. RESULTS: Bland-Altman analysis comparing direct IAP measurement with correspondent CPRS showed good agreement for IAP between 12 mm Hg and 30 mm Hg (bias -0.5 mm Hg, lower and upper limits of agreement (LLA/ULA) -3.5/2.5 mm Hg). FVP (bias -0.3 mm Hg, LLA/ULA -2.3/1.6 mm Hg) and IVP (bias 0.4 mm Hg, LLA/ULA -2.1/2.9 mm Hg) demonstrated similar results compared with direct IAP measurement. Agreement was worse for all indirect IAP measurement techniques for IAP<12 mm Hg. CONCLUSIONS: CPRS accurately reflects IAP for IAP> or =12 mm Hg. Accuracy is similar to established indirect IAP measurement techniques.

Citations

3 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 04 Jul 2010
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:15 June 2010
Deposited On:04 Jul 2010 14:13
Last Modified:05 Apr 2016 14:09
Publisher:Elsevier
ISSN:0022-4804
Publisher DOI:10.1016/j.jss.2008.11.849
PubMed ID:20371081
Permanent URL: http://doi.org/10.5167/uzh-34327

Download

[img]
Filetype: PDF - Registered users only
Size: 312kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations