Aortic valve prosthesis tracking for transapical aortic valve implantation


Karar, M E; Merk, D R; Chalopin, C; Walther, T; Falk, V; Burgert, O (2011). Aortic valve prosthesis tracking for transapical aortic valve implantation. International Journal of Computer Assisted Radiology and Surgery, 6(5):583-590.

Abstract

PURPOSE: Transapical aortic valve implantation (TA-AVI) is a new minimally invasive surgical treatment of aortic stenosis for high-risk patients. The placement of aortic valve prosthesis (AVP) is performed under 2D X-ray fluoroscopic guidance. Difficult clinical complications can arise if the implanted valve is misplaced. Therefore, we present a method to track the AVP in 2D X-ray fluoroscopic images in order to improve the accuracy of the TA-AVI. METHODS: The proposed tracking method includes the template matching approach to estimate the position of AVP and a shape model of the prosthesis to extract the corner points of the AVP in each image of sequence. To start the AVP tracking procedure, an initialization step is performed by manually defining the corner points of the prosthesis in the first image of sequence to provide the required algorithm parameters such as the AVP model parameters. RESULTS: We evaluated the AVP tracking method on six 2D intra-operative fluoroscopic image sequences. The results of automatic AVP localization agree well with manually defined AVP positions. The maximum localization errors of tracked prosthesis are less than 1 mm and within the clinical accepted range. CONCLUSIONS: For assisting the TA-AVI, a method for tracking the AVP in 2D X-ray fluoroscopic image sequences has been developed. Our AVP tracking method is a first step toward automatic optimal placement of the AVP during the TA-AVI.

PURPOSE: Transapical aortic valve implantation (TA-AVI) is a new minimally invasive surgical treatment of aortic stenosis for high-risk patients. The placement of aortic valve prosthesis (AVP) is performed under 2D X-ray fluoroscopic guidance. Difficult clinical complications can arise if the implanted valve is misplaced. Therefore, we present a method to track the AVP in 2D X-ray fluoroscopic images in order to improve the accuracy of the TA-AVI. METHODS: The proposed tracking method includes the template matching approach to estimate the position of AVP and a shape model of the prosthesis to extract the corner points of the AVP in each image of sequence. To start the AVP tracking procedure, an initialization step is performed by manually defining the corner points of the prosthesis in the first image of sequence to provide the required algorithm parameters such as the AVP model parameters. RESULTS: We evaluated the AVP tracking method on six 2D intra-operative fluoroscopic image sequences. The results of automatic AVP localization agree well with manually defined AVP positions. The maximum localization errors of tracked prosthesis are less than 1 mm and within the clinical accepted range. CONCLUSIONS: For assisting the TA-AVI, a method for tracking the AVP in 2D X-ray fluoroscopic image sequences has been developed. Our AVP tracking method is a first step toward automatic optimal placement of the AVP during the TA-AVI.

Citations

3 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

228 downloads since deposited on 15 Nov 2010
36 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2011
Deposited On:15 Nov 2010 12:45
Last Modified:05 Apr 2016 14:16
Publisher:Springer
ISSN:1861-6410
Publisher DOI:10.1007/s11548-010-0533-5
PubMed ID:20845084
Permanent URL: http://doi.org/10.5167/uzh-36142

Download

[img]
Preview
Filetype: PDF
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations