UZH-Logo

Maintenance Infos

Assessment of coronary sinus anatomy between normal and insufficient mitral valves by multi-slice computertomography for mitral annuloplasty device implantation


Plass, A; Valenta, I; Gaemperli, O; Kaufmann, P; Alkadhi, H; Zund, G; Grünenfelder, J; Genoni, M (2008). Assessment of coronary sinus anatomy between normal and insufficient mitral valves by multi-slice computertomography for mitral annuloplasty device implantation. European Journal of Cardio-Thoracic Surgery, 33(4):583-589.

Abstract

INTRODUCTION: Latest techniques enable positioning of devices into the coronary sinus (CS) for mitral valve (MV) annuloplasty. We evaluate the feasibility of non-invasive assessment to determine CS anatomy and its relation to MV annulus and coronary arteries by multi-slice CT (MSCT) in normal and insufficient MV. METHODS: Fifty patients (33 males, 17 females, age 67+/-11 years) were studied retrospectively by 64-MSCT scans for anatomical criteria regarding CS and its relation to MV annulus and circumflex artery (CX). We included 24 patients with severe mitral insufficiency and 26 with no MV disease. Diameter of MV, of proximal and distal ostium of CS, length and volume of CS, angle between anterior interventricular vein (AIV) and CS, caliber change of CX before, under/over and after CS were analysed. Different anatomical correlations were demonstrated: distance of MV annulus to CS, CX to CS. RESULTS: Diameter of proximal CS ostium was significantly larger in insufficient MV compared to normal MV (11+/-2.8 mm vs 9.9+/-2.5 mm; p<0.024). CS was significantly longer in patients with insufficient MV (125.4+/-17 mm vs 108.9+/-18 mm; p<0.003) with also significant differences in volume of CS (p<0.039). Significant difference in annulus diameter, 46.1+/-6mm (insufficient MV) versus 39.5+/-7.5 mm, p<0.004 was observed. Angle CS-AIV was 103.5+/-29 degrees (range 52 degrees -144 degrees ) in insufficient valves versus 118.2+/-24.5 degrees (range 73 degrees -166 degrees ) in normal valves with a tendency to higher angles in normal valves (p=0.06). Distance of MV annulus to CS measured 16+/-4.1/14.2+/-3.6 mm (insufficient/normal MV) without significant difference between groups. In 15 patients CX ran under CS. Eighty-four percent of these patients (13/15) show a decrease in CS caliber in the area of intersection. In 14 patients CS ran over and in one patient the diameter of the CS at intersecting region was smaller. In 16 patients no direct point of contact was visible, in five patients CX to CS positioning was not evaluable. CONCLUSION: There is a significant anatomic difference between normal and insufficient MV, which might be the basis for any interventional approaches through the CS. Exact measurements of all structures and its anatomic correlations are possible with MSCT, which allows pre-interventional planning.

Abstract

INTRODUCTION: Latest techniques enable positioning of devices into the coronary sinus (CS) for mitral valve (MV) annuloplasty. We evaluate the feasibility of non-invasive assessment to determine CS anatomy and its relation to MV annulus and coronary arteries by multi-slice CT (MSCT) in normal and insufficient MV. METHODS: Fifty patients (33 males, 17 females, age 67+/-11 years) were studied retrospectively by 64-MSCT scans for anatomical criteria regarding CS and its relation to MV annulus and circumflex artery (CX). We included 24 patients with severe mitral insufficiency and 26 with no MV disease. Diameter of MV, of proximal and distal ostium of CS, length and volume of CS, angle between anterior interventricular vein (AIV) and CS, caliber change of CX before, under/over and after CS were analysed. Different anatomical correlations were demonstrated: distance of MV annulus to CS, CX to CS. RESULTS: Diameter of proximal CS ostium was significantly larger in insufficient MV compared to normal MV (11+/-2.8 mm vs 9.9+/-2.5 mm; p<0.024). CS was significantly longer in patients with insufficient MV (125.4+/-17 mm vs 108.9+/-18 mm; p<0.003) with also significant differences in volume of CS (p<0.039). Significant difference in annulus diameter, 46.1+/-6mm (insufficient MV) versus 39.5+/-7.5 mm, p<0.004 was observed. Angle CS-AIV was 103.5+/-29 degrees (range 52 degrees -144 degrees ) in insufficient valves versus 118.2+/-24.5 degrees (range 73 degrees -166 degrees ) in normal valves with a tendency to higher angles in normal valves (p=0.06). Distance of MV annulus to CS measured 16+/-4.1/14.2+/-3.6 mm (insufficient/normal MV) without significant difference between groups. In 15 patients CX ran under CS. Eighty-four percent of these patients (13/15) show a decrease in CS caliber in the area of intersection. In 14 patients CS ran over and in one patient the diameter of the CS at intersecting region was smaller. In 16 patients no direct point of contact was visible, in five patients CX to CS positioning was not evaluable. CONCLUSION: There is a significant anatomic difference between normal and insufficient MV, which might be the basis for any interventional approaches through the CS. Exact measurements of all structures and its anatomic correlations are possible with MSCT, which allows pre-interventional planning.

Citations

13 citations in Web of Science®
14 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

18 downloads since deposited on 29 Sep 2008
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
04 Faculty of Medicine > University Hospital Zurich > Division of Surgical Research
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2008
Deposited On:29 Sep 2008 12:55
Last Modified:13 Sep 2016 07:29
Publisher:Elsevier
ISSN:1010-7940
Publisher DOI:https://doi.org/10.1016/j.ejcts.2007.12.041
PubMed ID:18255306

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.