Quick Search:

uzh logo
Browse by:
bullet
bullet
bullet
bullet

Zurich Open Repository and Archive 

Permanent URL to this publication: http://dx.doi.org/10.5167/uzh-3619

Plass, A; Valenta, I; Gaemperli, O; Kaufmann, P; Alkadhi, H; Zund, G; Grünenfelder, J; Genoni, M (2008). Assessment of coronary sinus anatomy between normal and insufficient mitral valves by multi-slice computertomography for mitral annuloplasty device implantation. European Journal of Cardio-Thoracic Surgery, 33(4):583-589.

[img]PDF - Registered users only
1458Kb

Abstract

INTRODUCTION: Latest techniques enable positioning of devices into the coronary sinus (CS) for mitral valve (MV) annuloplasty. We evaluate the feasibility of non-invasive assessment to determine CS anatomy and its relation to MV annulus and coronary arteries by multi-slice CT (MSCT) in normal and insufficient MV. METHODS: Fifty patients (33 males, 17 females, age 67+/-11 years) were studied retrospectively by 64-MSCT scans for anatomical criteria regarding CS and its relation to MV annulus and circumflex artery (CX). We included 24 patients with severe mitral insufficiency and 26 with no MV disease. Diameter of MV, of proximal and distal ostium of CS, length and volume of CS, angle between anterior interventricular vein (AIV) and CS, caliber change of CX before, under/over and after CS were analysed. Different anatomical correlations were demonstrated: distance of MV annulus to CS, CX to CS. RESULTS: Diameter of proximal CS ostium was significantly larger in insufficient MV compared to normal MV (11+/-2.8 mm vs 9.9+/-2.5 mm; p<0.024). CS was significantly longer in patients with insufficient MV (125.4+/-17 mm vs 108.9+/-18 mm; p<0.003) with also significant differences in volume of CS (p<0.039). Significant difference in annulus diameter, 46.1+/-6mm (insufficient MV) versus 39.5+/-7.5 mm, p<0.004 was observed. Angle CS-AIV was 103.5+/-29 degrees (range 52 degrees -144 degrees ) in insufficient valves versus 118.2+/-24.5 degrees (range 73 degrees -166 degrees ) in normal valves with a tendency to higher angles in normal valves (p=0.06). Distance of MV annulus to CS measured 16+/-4.1/14.2+/-3.6 mm (insufficient/normal MV) without significant difference between groups. In 15 patients CX ran under CS. Eighty-four percent of these patients (13/15) show a decrease in CS caliber in the area of intersection. In 14 patients CS ran over and in one patient the diameter of the CS at intersecting region was smaller. In 16 patients no direct point of contact was visible, in five patients CX to CS positioning was not evaluable. CONCLUSION: There is a significant anatomic difference between normal and insufficient MV, which might be the basis for any interventional approaches through the CS. Exact measurements of all structures and its anatomic correlations are possible with MSCT, which allows pre-interventional planning.

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
04 Faculty of Medicine > University Hospital Zurich > Division of Surgical Research
DDC:610 Medicine & health
Language:English
Date:2008
Deposited On:29 Sep 2008 14:55
Last Modified:27 Nov 2013 22:13
Publisher:Elsevier
ISSN:1010-7940
Publisher DOI:10.1016/j.ejcts.2007.12.041
PubMed ID:18255306
Citations:Web of Science®. Times Cited: 11
Google Scholar™

Users (please log in): suggest update or correction for this item

Repository Staff Only: item control page