Evaluation of biological aortic valve prostheses by dual source computer tomography and anatomic measurements for potential transapical valve-in-valve procedure


Grünenfelder, J; Plass, A; Alkadhi, H; Genoni, M (2008). Evaluation of biological aortic valve prostheses by dual source computer tomography and anatomic measurements for potential transapical valve-in-valve procedure. Interactive Cardiovascular and Thoracic Surgery, 7(2):195-200.

Abstract

Transapical aortic valve replacement has been introduced into clinical practice from which also patients with failing biological valves might profit: valve-in-valve procedure. The aim of the study was to determine the fate of biological valves in long-term follow-up (FU) and to evaluate topography and dimensions for transapical access via dual-source CT scan (DSCT). Fifty patients (mean age 76+/-13 years, range 38-87 years) underwent DSCT whereas the patients were followed for up to 13 years after porcine aortic valve replacement. Measurements of valve prosthesis and illustration of chest topography were done. Out of 46 evaluable patients, 34 showed no leaflet calcification and 12 minimally calcified. Seventeen valves (37%) showed no, 24 valves (52%) mild and 5 (11%) moderate-to-severe ring calcification. Three patients had moderate aortic stenosis, two patients showed mild insufficiency. The angle from the 4th ICS to apex to aortic valve annulus measured 80.3+/-11.1 degrees compared to the angle from the 5th ICS which measured 101.6+/-7.2 degrees (P<0.0001). Biological valves show good long-term results with minimal failure rate and limited calcification. Leaflet calcification might be problematic if unevenly distributed which can endanger the very close LCO. These measurements represent a prerequisite for preoperative planning and increase the awareness to detect potential procedural problems of the valve-in-valve concept.

Transapical aortic valve replacement has been introduced into clinical practice from which also patients with failing biological valves might profit: valve-in-valve procedure. The aim of the study was to determine the fate of biological valves in long-term follow-up (FU) and to evaluate topography and dimensions for transapical access via dual-source CT scan (DSCT). Fifty patients (mean age 76+/-13 years, range 38-87 years) underwent DSCT whereas the patients were followed for up to 13 years after porcine aortic valve replacement. Measurements of valve prosthesis and illustration of chest topography were done. Out of 46 evaluable patients, 34 showed no leaflet calcification and 12 minimally calcified. Seventeen valves (37%) showed no, 24 valves (52%) mild and 5 (11%) moderate-to-severe ring calcification. Three patients had moderate aortic stenosis, two patients showed mild insufficiency. The angle from the 4th ICS to apex to aortic valve annulus measured 80.3+/-11.1 degrees compared to the angle from the 5th ICS which measured 101.6+/-7.2 degrees (P<0.0001). Biological valves show good long-term results with minimal failure rate and limited calcification. Leaflet calcification might be problematic if unevenly distributed which can endanger the very close LCO. These measurements represent a prerequisite for preoperative planning and increase the awareness to detect potential procedural problems of the valve-in-valve concept.

Altmetrics

Downloads

4 downloads since deposited on 27 Oct 2008
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:April 2008
Deposited On:27 Oct 2008 16:26
Last Modified:13 Sep 2016 07:29
Publisher:European Association of Cardio-Thoracic Surgery
ISSN:1569-9285
Publisher DOI:10.1510/icvts.2007.166587
PubMed ID:18218653
Permanent URL: http://doi.org/10.5167/uzh-3620

Download

[img]
Filetype: PDF - Registered users only
Size: 391kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations