UZH-Logo

Maintenance Infos

In-vitro orthodontic bond strength testing: a systematic review and meta-analysis


Finnema, K J; Özcan, M; Post, W J; Ren, Y; Dijkstra, P U (2010). In-vitro orthodontic bond strength testing: a systematic review and meta-analysis. American Journal of Orthodontics and Dentofacial Orthopedics, 137(5):615-622.e3.

Abstract

INTRODUCTION: The aims of this study were to systematically review the available literature regarding in-vitro orthodontic shear bond strength testing and to analyze the influence of test conditions on bond strength.

METHODS: Our data sources were Embase and Medline. Relevant studies were selected based on predefined criteria. Study test conditions that might influence in-vitro bond strength were independently assessed by 2 observers. Studies reporting a minimum number of test conditions were included for meta-analysis by using a multilevel model with 3 levels, with author as the highest level, study as the second level, and specimens in the study as the lowest level. The primary outcome measure was bond strength.

RESULTS: We identified 121 relevant studies, of which 24 were included in the meta-analysis. Methodologic drawbacks of the excluded studies were generally related to inadequate reporting of test conditions and specimen storage. The meta-analysis demonstrated that 3 experimental conditions significantly affect in-vitro bond strength testing. Although water storage decreased bond strength on average by 10.7 MPa, each second of photopolymerization time and each millimeter per minute of greater crosshead speed increased bond strength by 0.077 and 1.3 MPa, respectively.

CONCLUSIONS: Many studies on in-vitro orthodontic bond strength fail to report test conditions that could significantly affect their outcomes.
Copyright (c) 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

INTRODUCTION: The aims of this study were to systematically review the available literature regarding in-vitro orthodontic shear bond strength testing and to analyze the influence of test conditions on bond strength.

METHODS: Our data sources were Embase and Medline. Relevant studies were selected based on predefined criteria. Study test conditions that might influence in-vitro bond strength were independently assessed by 2 observers. Studies reporting a minimum number of test conditions were included for meta-analysis by using a multilevel model with 3 levels, with author as the highest level, study as the second level, and specimens in the study as the lowest level. The primary outcome measure was bond strength.

RESULTS: We identified 121 relevant studies, of which 24 were included in the meta-analysis. Methodologic drawbacks of the excluded studies were generally related to inadequate reporting of test conditions and specimen storage. The meta-analysis demonstrated that 3 experimental conditions significantly affect in-vitro bond strength testing. Although water storage decreased bond strength on average by 10.7 MPa, each second of photopolymerization time and each millimeter per minute of greater crosshead speed increased bond strength by 0.077 and 1.3 MPa, respectively.

CONCLUSIONS: Many studies on in-vitro orthodontic bond strength fail to report test conditions that could significantly affect their outcomes.
Copyright (c) 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Citations

20 citations in Web of Science®
21 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

3 downloads since deposited on 06 Feb 2011
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2010
Deposited On:06 Feb 2011 10:01
Last Modified:05 Apr 2016 14:43
Publisher:Elsevier
ISSN:0889-5406
Publisher DOI:https://doi.org/10.1016/j.ajodo.2009.12.021
PubMed ID:20451780
Permanent URL: https://doi.org/10.5167/uzh-44693

Download

[img]
Filetype: PDF (Verlags-PDF) - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.