In-vivo assessment of tissue metabolite levels using 1H MRS and the Electric REference To access In vivo Concentrations (ERETIC) method


Heinzer-Schweizer, S; De Zanche, N; Pavan, M; Mens, G; Sturzenegger, U; Henning, A; Boesiger, P (2010). In-vivo assessment of tissue metabolite levels using 1H MRS and the Electric REference To access In vivo Concentrations (ERETIC) method. NMR in Biomedicine, 23(4):406-413.

Abstract

Quantitative values of metabolite concentrations in (1)H magnetic resonance spectroscopy have been obtained using the Electric REference To access In vivo Concentrations (ERETIC) method, whereby a synthetic reference signal is injected during the acquisition of spectra. The method has been improved to enable quantification of metabolite concentrations in vivo. Optical signal transmission was used to eliminate random fluctuations in ERETIC signal coupling to the receiver coil due to changes in position of cables and highly dielectric human tissue. Stability and reliability of the signal were tested in vitro, achieving stability with a mean error of 2.83%. Scaling of the signal in variable loading conditions was demonstrated and in-vivo measurements of brain were acquired on a 3T Philips system using a transmit/receive coil. The quantitative brain water and metabolite concentration values are in good agreement with those in the literature.

Abstract

Quantitative values of metabolite concentrations in (1)H magnetic resonance spectroscopy have been obtained using the Electric REference To access In vivo Concentrations (ERETIC) method, whereby a synthetic reference signal is injected during the acquisition of spectra. The method has been improved to enable quantification of metabolite concentrations in vivo. Optical signal transmission was used to eliminate random fluctuations in ERETIC signal coupling to the receiver coil due to changes in position of cables and highly dielectric human tissue. Stability and reliability of the signal were tested in vitro, achieving stability with a mean error of 2.83%. Scaling of the signal in variable loading conditions was demonstrated and in-vivo measurements of brain were acquired on a 3T Philips system using a transmit/receive coil. The quantitative brain water and metabolite concentration values are in good agreement with those in the literature.

Citations

23 citations in Web of Science®
24 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 22 Feb 2011
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2010
Deposited On:22 Feb 2011 09:25
Last Modified:05 Apr 2016 14:45
Publisher:Wiley-Blackwell
ISSN:0952-3480
Publisher DOI:https://doi.org/10.1002/nbm.1476
PubMed ID:20101606

Download

[img]
Filetype: PDF - Registered users only
Size: 340kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations