Quick Search:

uzh logo
Browse by:
bullet
bullet
bullet
bullet

Zurich Open Repository and Archive

Permanent URL to this publication: http://dx.doi.org/10.5167/uzh-45826

Goetti, R; Leschka, S; Boschung, M; Mayer, S; Wyss, C; Stolzmann, P; Frauenfelder, T (2012). Radiation doses from phantom measurements at high-pitch dual-source computed tomography coronary angiography. European Journal of Radiology, 81(4):773-779.

[img] PDF - Registered users only
1MB

View at publisher

Abstract

OBJECTIVE: To compare radiation doses delivered at prospectively ECG-triggered sequential- (SEQ), retrospectively ECG-gated spiral- (RETRO) and prospectively ECG-triggered high-pitch spiral- (HP) computed tomography coronary angiography (CTCA) protocols, as well as catheter coronary angiography (CCA) using an anthropomorphic phantom. MATERIALS AND METHODS: An anthropomorphic Alderson phantom equipped with 50 thermoluminescent dosimeters (TLDs) was scanned using different CTCA protocols and an uncomplicated diagnostic CCA examination was simulated. Absorbed doses were experimentally determined and effective doses calculated using the dose-length product (DLP) for CTCA and the dose-area product (DAP) for CCA, as well as according to International Commission on Radiation Protection (ICRP) publications 60 and 103. RESULTS: Effective organ doses were significantly lower for HP protocols (100kV: 0.17±0.26mSv; 120kV: 0.26±0.39mSv) compared to SEQ protocols (100kV: 0.50±0.79mSv; 120kV: 0.90±1.41mSv; each p<0.05) and compared to RETRO protocols (100kV: 1.59±2.12mSv; 120kV: 2.75±3.50mSv; each p<0.05). Effective organ doses at HP-CTCA tended to be lower than at CCA (0.37±0.40mSv), however this was not statistically significant (p=0.13). Effective doses calculated according to ICRP guidelines could be estimated using the DLP and a conversion coefficient of k=0.034mSv/[mGycm] (ICRP103) or k=0.028mSv/[mGycm] (ICRP60), respectively. HP-CTCA led to a dose reduction of 89% compared to RETRO-CTCA, regardless of the calculation method used. CONCLUSIONS: Radiation doses as determined by phantom measurements are significantly lower at HP-CTCA compared to SEQ-CTCA and RETRO-CTCA and comparable to uncomplicated diagnostic CCA.

Citations

4 citations in Web of Science®
4 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 16 Feb 2011
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
DDC:610 Medicine & health
Language:English
Date:2012
Deposited On:16 Feb 2011 16:30
Last Modified:28 Nov 2013 00:15
Publisher:Elsevier
ISSN:0720-048X
Publisher DOI:10.1016/j.ejrad.2011.01.068
PubMed ID:21310565

Users (please log in): suggest update or correction for this item

Repository Staff Only: item control page