UZH-Logo

Maintenance Infos

Do iatrogenic factors bias the placement of external ventricular catheters? A single institute experience and review of the literature


Woernle, C M; Burkhardt, J K; Bellut, D; Krayenbuehl, N; Bertalanffy, H (2011). Do iatrogenic factors bias the placement of external ventricular catheters? A single institute experience and review of the literature. Neurologia Medico-Chirurgica, 51(3):180-186.

Abstract

Placement of external ventricular drainage (EVD) catheters is the gold standard for managing acute hydrocephalus, but the range of complications varies in different studies. The objective of this present single institute study is to analyze iatrogenic factors, which may influence the EVD device placement and the patient's outcome. A total of 137 EVD placements in 120 patients at the University Hospital Zurich were analyzed retrospectively. Discriminative findings between the pre- and postoperative imaging were obtained and evaluated in detail with regards to the postoperative course, ventriculostomy-related infection, and acute neurological deterioration directly related to the EVD placement. These findings were correlated to iatrogenic factors including education level of the neurosurgeon and surgical setting. Overall EVD-related complication rate was 16.1%, including infection rate of 10.2%, catheter malplacement rate of 2.2%, and hemorrhage rate of 3.6%. Although not statistically significant, catheter-associated hemorrhages and malplacements were found mostly in primary EVD surgery, with a higher complication rate associated with junior residents as the performing surgeon. In contrast, ventriculostomy-related infection was most likely present in patients with more than one EVD placement and in patients treated by more experienced physicians. Complications related to EVD are common. The rate and character of the complication depends on the education level of the surgeon.

Placement of external ventricular drainage (EVD) catheters is the gold standard for managing acute hydrocephalus, but the range of complications varies in different studies. The objective of this present single institute study is to analyze iatrogenic factors, which may influence the EVD device placement and the patient's outcome. A total of 137 EVD placements in 120 patients at the University Hospital Zurich were analyzed retrospectively. Discriminative findings between the pre- and postoperative imaging were obtained and evaluated in detail with regards to the postoperative course, ventriculostomy-related infection, and acute neurological deterioration directly related to the EVD placement. These findings were correlated to iatrogenic factors including education level of the neurosurgeon and surgical setting. Overall EVD-related complication rate was 16.1%, including infection rate of 10.2%, catheter malplacement rate of 2.2%, and hemorrhage rate of 3.6%. Although not statistically significant, catheter-associated hemorrhages and malplacements were found mostly in primary EVD surgery, with a higher complication rate associated with junior residents as the performing surgeon. In contrast, ventriculostomy-related infection was most likely present in patients with more than one EVD placement and in patients treated by more experienced physicians. Complications related to EVD are common. The rate and character of the complication depends on the education level of the surgeon.

Citations

10 citations in Web of Science®
12 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

295 downloads since deposited on 16 Jun 2011
38 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Neurosurgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2011
Deposited On:16 Jun 2011 09:18
Last Modified:05 Apr 2016 14:56
Publisher:Japan Neurosurgical Society
ISSN:0470-8105
Publisher DOI:https://doi.org/10.2176/nmc.51.180
PubMed ID:21441733
Permanent URL: https://doi.org/10.5167/uzh-48373

Download

[img]
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher
[img]
Preview
Content: Published Version
Filetype: PDF
Size: 120kB

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations