UZH-Logo

Maintenance Infos

Flexural strength of veneering ceramics for zirconia


Fischer, J; Stawarczyk, B; Hämmerle, C H F (2008). Flexural strength of veneering ceramics for zirconia. Journal of Dentistry, 36(5):316-321.

Abstract

OBJECTIVES: The flexural strengths of veneering ceramics for zirconia were compared. METHODS: With 10 different veneering ceramics for zirconia (test group) and three different veneering ceramics for the metal-ceramic technique (control group) three-point flexural strength and biaxial flexural strength according to ISO 6872: 1995 as well as four-point flexural strength according to EN 843-1: 2005 were measured (n=10). Statistical analysis was performed with one-way ANOVA and post hoc Scheffé test (SPSS, p<0.05). RESULTS: For the test group, three-point flexural strength ranged between 77.8+/-8.7 and 106.6+/-12.5MPa without any statistically significant differences, biaxial flexural strength between 69.1+/-4.8 and 101.4+/-10.5MPa with three homogeneous groups and four-point flexural strength between 59.5+/-6.2 and 89.2+/-9.5MPa with five homogeneous groups. The control group showed three-point flexural strength values ranging from 93.3+/-13.5 to 149.4+/-20.5MPa, biaxial flexural strength values from 93.4+/-10.0 to 141.2+/-11.6MPa, and four-point flexural strength values from 82.7+/-8.5 to 116.9+/-9.8MPa. In every case, the results of the four-point flexure test were significantly lower than those obtained in the three-point flexure test. The three-point flexural strengths of the test group are similar to those of two ceramics of the control group. The flexural strength of one ceramic of the control group significantly exceeded the strengths of all other ceramics investigated. CONCLUSION: Three-point flexural strength values of veneering ceramics for zirconia are similar to those of veneering ceramics for the metal-ceramic technique. The four-point flexure test among all three tests showed highest discrimination between the different ceramic materials.

OBJECTIVES: The flexural strengths of veneering ceramics for zirconia were compared. METHODS: With 10 different veneering ceramics for zirconia (test group) and three different veneering ceramics for the metal-ceramic technique (control group) three-point flexural strength and biaxial flexural strength according to ISO 6872: 1995 as well as four-point flexural strength according to EN 843-1: 2005 were measured (n=10). Statistical analysis was performed with one-way ANOVA and post hoc Scheffé test (SPSS, p<0.05). RESULTS: For the test group, three-point flexural strength ranged between 77.8+/-8.7 and 106.6+/-12.5MPa without any statistically significant differences, biaxial flexural strength between 69.1+/-4.8 and 101.4+/-10.5MPa with three homogeneous groups and four-point flexural strength between 59.5+/-6.2 and 89.2+/-9.5MPa with five homogeneous groups. The control group showed three-point flexural strength values ranging from 93.3+/-13.5 to 149.4+/-20.5MPa, biaxial flexural strength values from 93.4+/-10.0 to 141.2+/-11.6MPa, and four-point flexural strength values from 82.7+/-8.5 to 116.9+/-9.8MPa. In every case, the results of the four-point flexure test were significantly lower than those obtained in the three-point flexure test. The three-point flexural strengths of the test group are similar to those of two ceramics of the control group. The flexural strength of one ceramic of the control group significantly exceeded the strengths of all other ceramics investigated. CONCLUSION: Three-point flexural strength values of veneering ceramics for zirconia are similar to those of veneering ceramics for the metal-ceramic technique. The four-point flexure test among all three tests showed highest discrimination between the different ceramic materials.

Citations

58 citations in Web of Science®
59 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

249 downloads since deposited on 04 Nov 2008
17 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:May 2008
Deposited On:04 Nov 2008 10:33
Last Modified:05 Apr 2016 12:32
Publisher:Elsevier
ISSN:0300-5712
Publisher DOI:10.1016/j.jdent.2008.01.017
PubMed ID:18339469
Permanent URL: http://doi.org/10.5167/uzh-5087

Download

[img]
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.