UZH-Logo

Maintenance Infos

Comparison of thromboelastometry (ROTEM(R)) with standard plasmatic coagulation testing in paediatric surgery


Haas, T; Spielmann, N; Mauch, J; Madjdpour, C; Speer, O; Schmugge, M; Weiss, M (2012). Comparison of thromboelastometry (ROTEM(R)) with standard plasmatic coagulation testing in paediatric surgery. British Journal of Anaesthesia, 108(1):36-41.

Abstract

Background. Thromboelastometry (ROTEM(R)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests.
Methods. Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen level] and ROTEM(R) analyses (InTEM, ExTEM, and FibTEM) were performed simultaneously by trained hospital laboratory staff.
Results. A total of 288 blood samples from 50 subjects were analysed. While there was a poor correlation between PT and aPTT to ExTEM clotting time (CT) and InTEM CT, respectively, a good correlation was detected between PT and aPTT to clot formation time, and a very good correlation between fibrinogen level and FibTEM assay (r=0.882, P<0.001). Notably, 64% of PT and 94% of aPTT measurements were outside the reference range, while impaired CT was observed in 13% and 6.3%, respectively. Standard coagulation test results were available after a median of 53 min [inter-quartile range (IQR): 45–63 min], whereas 10 min values of ROTEM(R) results were available online after 23 min (IQR: 21–24 min).
Conclusions. PT and aPTT cannot be interchangeably used with ROTEM(R) CT. Based on the results of ROTEM(R), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM(R) offered faster turnaround times.

Abstract

Background. Thromboelastometry (ROTEM(R)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests.
Methods. Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen level] and ROTEM(R) analyses (InTEM, ExTEM, and FibTEM) were performed simultaneously by trained hospital laboratory staff.
Results. A total of 288 blood samples from 50 subjects were analysed. While there was a poor correlation between PT and aPTT to ExTEM clotting time (CT) and InTEM CT, respectively, a good correlation was detected between PT and aPTT to clot formation time, and a very good correlation between fibrinogen level and FibTEM assay (r=0.882, P<0.001). Notably, 64% of PT and 94% of aPTT measurements were outside the reference range, while impaired CT was observed in 13% and 6.3%, respectively. Standard coagulation test results were available after a median of 53 min [inter-quartile range (IQR): 45–63 min], whereas 10 min values of ROTEM(R) results were available online after 23 min (IQR: 21–24 min).
Conclusions. PT and aPTT cannot be interchangeably used with ROTEM(R) CT. Based on the results of ROTEM(R), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM(R) offered faster turnaround times.

Citations

72 citations in Web of Science®
84 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 18 Nov 2011
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
04 Faculty of Medicine > Center for Integrative Human Physiology
04 Faculty of Medicine > University Hospital Zurich > Institute of Anesthesiology
04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
Dewey Decimal Classification:570 Life sciences; biology
610 Medicine & health
Language:English
Date:2012
Deposited On:18 Nov 2011 08:43
Last Modified:05 Apr 2016 15:06
Publisher:Oxford University Press
ISSN:0007-0912
Publisher DOI:https://doi.org/10.1093/bja/aer342

Download

[img]
Content: Published Version
Filetype: PDF - Registered users only
Size: 357kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations