Abstract

To fit high-density receiver arrays for MRI closely around individual target anatomies, there is a need to provide a high degree of geometric adjustability with ease of handling and patient comfort. In this work, this is accomplished by the construction of a coil array that is stretchable such that it automatically conforms to a given anatomy's shape and size. Stretchability is implemented by creating the coil conductors from braided wire mounted on an elastic textile substrate. The signal-to-noise ratio yield of such coils is measured by MRI experiments at 3 T, and the signal-to-noise ratio effect of coil stretching is investigated with and without adjustment of the matching between each coil and the respective preamplifier. Four-channel and eight-channel arrays of stretchable receiver coils are evaluated in phantoms as well as for in vivo imaging of the human knee. Exploiting stretchability, it is demonstrated that the knee can be imaged under varying flexion angles up to 60° while maintaining closely coupled array detection, high signal-to-noise ratio, and uniform coverage of the entire joint. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.

To fit high-density receiver arrays for MRI closely around individual target anatomies, there is a need to provide a high degree of geometric adjustability with ease of handling and patient comfort. In this work, this is accomplished by the construction of a coil array that is stretchable such that it automatically conforms to a given anatomy's shape and size. Stretchability is implemented by creating the coil conductors from braided wire mounted on an elastic textile substrate. The signal-to-noise ratio yield of such coils is measured by MRI experiments at 3 T, and the signal-to-noise ratio effect of coil stretching is investigated with and without adjustment of the matching between each coil and the respective preamplifier. Four-channel and eight-channel arrays of stretchable receiver coils are evaluated in phantoms as well as for in vivo imaging of the human knee. Exploiting stretchability, it is demonstrated that the knee can be imaged under varying flexion angles up to 60° while maintaining closely coupled array detection, high signal-to-noise ratio, and uniform coverage of the entire joint. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.

Citations

4 citations in Web of Science®
5 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 22 Jan 2012
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2012
Deposited On:22 Jan 2012 20:08
Last Modified:05 Apr 2016 15:27
Publisher:Wiley-Blackwell
ISSN:0740-3194
Publisher DOI:10.1002/mrm.23240
PubMed ID:22213018
Permanent URL: http://doi.org/10.5167/uzh-56452

Download

[img]Content: Published Version
Filetype: PDF (Article in press) - Registered users only
Size: 820kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations