UZH-Logo

Patient-specific simulations and measurements of the magneto-hemodynamic effect in human primary vessels


Kyriakou, A; Neufeld, E; Szczerba, D; Kainz, W; Luechinger, R; Kozerke, S; McGregor, R; Kuster, N (2012). Patient-specific simulations and measurements of the magneto-hemodynamic effect in human primary vessels. Physiological Measurement, 33(2):117-130.

Abstract

This paper investigates the main characteristics of the magneto-hemodynamic (MHD) response for application as a biomarker of vascular blood flow. The induced surface potential changes of a volunteer exposed to a 3 T static B0 field of a magnetic resonance imaging (MRI) magnet were measured over time at multiple locations by an electrocardiogram device and compared to simulation results. The flow simulations were based on boundary conditions derived from MRI flow measurements restricted to the aorta and vena cava. A dedicated and validated low-frequency electromagnetic solver was applied to determine the induced temporal surface potential change from the obtained 4D flow distribution using a detailed whole-body model of the volunteer. The simulated MHD signal agreed with major characteristics of the measured signal (temporal location of main peak, magnitude, variation across chest and along torso) except in the vicinity of the heart. The MHD signal is mostly influenced by the aorta; however, more vessels and better boundary conditions are needed to analyze the finer details of the response. The results show that the MHD signal is strongly position dependent with highly variable but reproducibly measurable distinguished characteristics. Additional investigations are necessary before determining whether the MHD effect is a reliable reference for location-specific information on blood flow.

This paper investigates the main characteristics of the magneto-hemodynamic (MHD) response for application as a biomarker of vascular blood flow. The induced surface potential changes of a volunteer exposed to a 3 T static B0 field of a magnetic resonance imaging (MRI) magnet were measured over time at multiple locations by an electrocardiogram device and compared to simulation results. The flow simulations were based on boundary conditions derived from MRI flow measurements restricted to the aorta and vena cava. A dedicated and validated low-frequency electromagnetic solver was applied to determine the induced temporal surface potential change from the obtained 4D flow distribution using a detailed whole-body model of the volunteer. The simulated MHD signal agreed with major characteristics of the measured signal (temporal location of main peak, magnitude, variation across chest and along torso) except in the vicinity of the heart. The MHD signal is mostly influenced by the aorta; however, more vessels and better boundary conditions are needed to analyze the finer details of the response. The results show that the MHD signal is strongly position dependent with highly variable but reproducibly measurable distinguished characteristics. Additional investigations are necessary before determining whether the MHD effect is a reliable reference for location-specific information on blood flow.

Citations

8 citations in Web of Science®
8 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 30 Mar 2012
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2012
Deposited On:30 Mar 2012 07:56
Last Modified:05 Apr 2016 15:27
Publisher:Institute of Physics Publishing
ISSN:0967-3334
Publisher DOI:10.1088/0967-3334/33/2/117
PubMed ID:22227810
Permanent URL: http://doi.org/10.5167/uzh-56463

Download

[img]
Content: Published Version
Filetype: PDF - Registered users only
Size: 2MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations