Small animal Look-Locker inversion recovery (SALLI) for simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates: initial experience


Messroghli, D R; Nordmeyer, S; Buehrer, M; Kozerke, S; Dietrich, T; Kaschina, E; Becher, P M; Hucko, T; Berger, F; Klein, C; Kuehne, T (2011). Small animal Look-Locker inversion recovery (SALLI) for simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates: initial experience. Radiology, 261(1):258-265.

Abstract

Phantom studies demonstrated systematic behavior of the T1 measurements, and T1 error could be reduced to 1.3% ± 7.4 by using a simple linear correction algorithm. The pre- and postcontrast T1 of myocardium and blood showed narrow normal ranges. In the area of infarction, SALLI demonstrated hypokinesia (on cine images), myocardial edema (on precontrast T1 maps), and myocardial necrosis (on postcontrast T1 maps and late gadolinium enhancement images). Conclusion: An MR imaging method enabling simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates is presented. SALLI allows for simultaneous and time-efficient assessment of cardiac T1 behavior, function, and late gadolinium enhancement at high heart rates.

Phantom studies demonstrated systematic behavior of the T1 measurements, and T1 error could be reduced to 1.3% ± 7.4 by using a simple linear correction algorithm. The pre- and postcontrast T1 of myocardium and blood showed narrow normal ranges. In the area of infarction, SALLI demonstrated hypokinesia (on cine images), myocardial edema (on precontrast T1 maps), and myocardial necrosis (on postcontrast T1 maps and late gadolinium enhancement images). Conclusion: An MR imaging method enabling simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates is presented. SALLI allows for simultaneous and time-efficient assessment of cardiac T1 behavior, function, and late gadolinium enhancement at high heart rates.

Citations

10 citations in Web of Science®
11 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2011
Deposited On:28 Jan 2012 14:51
Last Modified:05 Apr 2016 15:27
Publisher:Radiological Society of North America
ISSN:0033-8419
Publisher DOI:10.1148/radiol.11101943
PubMed ID:21788528

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.