Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study


Papaspyridakos, P; Benić, G I; Hogsett, V L; White, G S; Lal, K; Gallucci, G O (2012). Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clinical Oral Implants Research, 23(6):676-681.

Abstract

Background: The accuracy of implant casts generated with various impression techniques was mainly investigated in vitro resulting in limited clinical data. Purpose: (1) To compare the three-dimensional (3-D) accuracy of splinted and non-splinted impression techniques to the control casts (verification jigs) that had been used for actual patient treatment; and (2) to determine the maximum level of clinically undetectable misfit. The null hypothesis was that there would be no significant difference in the accuracy of casts generated with different impression techniques. Materials and methods: The implant casts used for the prosthetic rehabilitation of 12 edentulous jaws with CAD/CAM zirconia, implant-fixed complete dental prosthesis (IFCDP) were included in this study. Intraoral acrylic jigs were used to fabricate index casts. Splinted and non-splinted, open-tray techniques were used to generate two casts. Optical scanning acquisition of the x-coordinates, y-coordinates and z-coordinates of the implant positions for each individual cast was performed. The "best fit" algorithm was used with computer software to superimpose the scanning datasets. Group I (n=12) included casts from the splinted impression technique vs. acrylic jig casts, and group II (n=12) included casts from non-splinted technique vs. jig casts. Results: The paired t-test and Wilcoxon's signed ranks test were used to compare the 3-D discrepancies within and between groups I (splinted vs. jig) and II (non-splinted vs. jig), respectively. Significant difference was found at the x-axis, y-axis and 3-D between groups I and II (P<0.05), but not in the vertical z-axis (P>0.05). Within subject, global 3-D discrepancies between groups I and II were significantly different (P<0.05), corroborated by in vivo observations of clinical fit. Implant position in the arch affected the 3-D accuracy of casts for both anterior and posterior implants (P<0.05). Conclusion: The splinted technique generated more accurate master casts than the non-splinted technique for one-piece IFCDPs in edentulous jaws and the null hypothesis was rejected. These clinical implications demonstrate improved accuracy of splinted impression techniques compared with the non-splinted technique. For the external connection, the implant system used in this study, a 3-D misfit ranging from 59 to 72 μm, may be considered the maximum discrepancy resulting in an acceptable clinical fit with one-piece IFCDPs. To cite this article: Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clin. Oral Impl. Res. xx, 2011; 000-000. doi: 10.1111/j.1600-0501.2011.02219.x.

Abstract

Background: The accuracy of implant casts generated with various impression techniques was mainly investigated in vitro resulting in limited clinical data. Purpose: (1) To compare the three-dimensional (3-D) accuracy of splinted and non-splinted impression techniques to the control casts (verification jigs) that had been used for actual patient treatment; and (2) to determine the maximum level of clinically undetectable misfit. The null hypothesis was that there would be no significant difference in the accuracy of casts generated with different impression techniques. Materials and methods: The implant casts used for the prosthetic rehabilitation of 12 edentulous jaws with CAD/CAM zirconia, implant-fixed complete dental prosthesis (IFCDP) were included in this study. Intraoral acrylic jigs were used to fabricate index casts. Splinted and non-splinted, open-tray techniques were used to generate two casts. Optical scanning acquisition of the x-coordinates, y-coordinates and z-coordinates of the implant positions for each individual cast was performed. The "best fit" algorithm was used with computer software to superimpose the scanning datasets. Group I (n=12) included casts from the splinted impression technique vs. acrylic jig casts, and group II (n=12) included casts from non-splinted technique vs. jig casts. Results: The paired t-test and Wilcoxon's signed ranks test were used to compare the 3-D discrepancies within and between groups I (splinted vs. jig) and II (non-splinted vs. jig), respectively. Significant difference was found at the x-axis, y-axis and 3-D between groups I and II (P<0.05), but not in the vertical z-axis (P>0.05). Within subject, global 3-D discrepancies between groups I and II were significantly different (P<0.05), corroborated by in vivo observations of clinical fit. Implant position in the arch affected the 3-D accuracy of casts for both anterior and posterior implants (P<0.05). Conclusion: The splinted technique generated more accurate master casts than the non-splinted technique for one-piece IFCDPs in edentulous jaws and the null hypothesis was rejected. These clinical implications demonstrate improved accuracy of splinted impression techniques compared with the non-splinted technique. For the external connection, the implant system used in this study, a 3-D misfit ranging from 59 to 72 μm, may be considered the maximum discrepancy resulting in an acceptable clinical fit with one-piece IFCDPs. To cite this article: Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clin. Oral Impl. Res. xx, 2011; 000-000. doi: 10.1111/j.1600-0501.2011.02219.x.

Citations

26 citations in Web of Science®
20 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 22 Feb 2012
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2012
Deposited On:22 Feb 2012 16:27
Last Modified:05 Apr 2016 15:36
Publisher:Wiley-Blackwell
ISSN:0905-7161
Publisher DOI:https://doi.org/10.1111/j.1600-0501.2011.02219.x
PubMed ID:21631595

Download

[img]
Content: Published Version
Language: English
Filetype: PDF - Registered users only
Size: 691kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations