UZH-Logo

Maintenance Infos

Cochlear Implant Impedance Telemetry Measurements and Model Calculations to Estimate Modiolar Currents


von Rohr, R. Cochlear Implant Impedance Telemetry Measurements and Model Calculations to Estimate Modiolar Currents. 2011, University of Zurich, Faculty of Medicine.

Abstract

The use of impedance and neural response telemetry measurements through stimulation and recording of electrical signals can facilitate device fitting and parameter adjustments, especially in young children. However, the detailed configuration of electrical impedances and current distributions around the electrode array is unknown and has not been able to be determined using standard impedance telemetry measures. We therefore attempted to improve the impedance measurement procedure
by applying a more detailed model of electrical impedances of stimulation and recording electrodes within the cochlea and by developing more sophisticated measurement protocols to identify the model parameters in a given implant subject. In particular, the modiolar currents, the portion of the currents assumed to be responsible for activating the neural elements, are determined and evaluated.
Their predictive value for device fitting parameters is being investigated and first results have been obtained by a series of postoperative and intraoperative measurements,
which will allow us to estimate changes of the modiolar current distributions over the first weeks after implantation.
This approach is mainly based on a published patent, and makes use of the Nucleus Matlab Toolbox and the Nucleus Implant Communicator (NIC) software. The ultimate goals of a refined model and more specific impedance measurements are
semiautomatic fitting and of programming parameter update procedures for CI users with varying electrical stimulation conditions.

The use of impedance and neural response telemetry measurements through stimulation and recording of electrical signals can facilitate device fitting and parameter adjustments, especially in young children. However, the detailed configuration of electrical impedances and current distributions around the electrode array is unknown and has not been able to be determined using standard impedance telemetry measures. We therefore attempted to improve the impedance measurement procedure
by applying a more detailed model of electrical impedances of stimulation and recording electrodes within the cochlea and by developing more sophisticated measurement protocols to identify the model parameters in a given implant subject. In particular, the modiolar currents, the portion of the currents assumed to be responsible for activating the neural elements, are determined and evaluated.
Their predictive value for device fitting parameters is being investigated and first results have been obtained by a series of postoperative and intraoperative measurements,
which will allow us to estimate changes of the modiolar current distributions over the first weeks after implantation.
This approach is mainly based on a published patent, and makes use of the Nucleus Matlab Toolbox and the Nucleus Implant Communicator (NIC) software. The ultimate goals of a refined model and more specific impedance measurements are
semiautomatic fitting and of programming parameter update procedures for CI users with varying electrical stimulation conditions.

Downloads

186 downloads since deposited on 15 Feb 2012
66 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Dissertation
Referees:Dillier N
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Otorhinolaryngology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2011
Deposited On:15 Feb 2012 09:07
Last Modified:05 Apr 2016 15:37
Number of Pages:49
Permanent URL: https://doi.org/10.5167/uzh-59165

Download

[img]
Preview
Language: English
Filetype: PDF
Size: 2MB

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations