Permanent URL to this publication: http://dx.doi.org/10.5167/uzh-63883
Bektas, R N; Kutter, A P N; Hartnack, S; Jud, R; Schnyder, M; Matos, J M; Bettschart-Wolfensberger, R (2012). Evaluation of a minimally invasive non-calibrated pulse contour cardiac output monitor (FloTrac/Vigileo) in anaesthetized dogs. Veterinary Anaesthesia and Analgesia, 39(5):464-471.
| Published Version PDF - Registered users only 358Kb | ||
| Accepted Version PDF - Registered users only 139Kb |
Abstract
Objective To evaluate the accuracy of a new cardiac output monitor (FloTrac/Vigileo), originally designed for humans, in dogs. This pulse contour cardiac output monitoring system cannot be calibrated and measures cardiac output (Q̇t) from a standard arterial catheter. Study design Prospective experimental trial. Animals Eight adult Beagle dogs weighing 13.1 (9.8-17.1) kg [median (range)]. Methods Anaesthesia in the dogs was maintained using isoflurane. A pulmonary artery catheter and a metatarsal arterial catheter (22 gauge) were placed. Cardiac output was measured simultaneously 331 times by thermodilution and FloTrac technique. A broad spectrum of Q̇t measurements was achieved through alterations of isoflurane concentration, administration of propofol boluses and dobutamine infusions. Agreement between the methods was quantified with Bland Altman analysis and disagreement was assessed with linear mixed models. Results Median (10th and 90th percentile) cardiac output as measured with thermodilution was 2.54 (1.47 and 5.15) L minute(-1) and as measured with FloTrac 8.6 (3.9 and 17.3) L minute(-1) . FloTrac measurements were consistently higher with a mean bias of 7 L minute(-1) and limits of agreement of -3.15 to 17.17 L minute(-1) . Difference between the methods was most pronounced in high Q̇t measurements. Linear mixed models showed an estimated difference between the two methods of 8.05 (standard error 1.18) L minute(-1) and a significant interaction between mean arterial pressure and method. Standard deviation (4.45 higher) with the FloTrac method compared to thermodilution was increased. Conclusion Compared to thermodilution measurements, the FloTrac system was influenced to a higher degree by arterial blood pressure, resulting in consistent overestimation of cardiac output. Clinical Relevance The FloTrac monitor, whose algorithms were developed based on human data, cannot be used as an alternative for thermodilution in dogs.
| Item Type: | Journal Article, refereed, original work |
|---|---|
| Communities & Collections: | 05 Vetsuisse Faculty > Institute of Parasitology 04 Faculty of Medicine > Institute of Parasitology 05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals > Clinic for Small Animal Internal Medicine 05 Vetsuisse Faculty > Chair in Veterinary Epidemiology 05 Vetsuisse Faculty > Veterinary Clinic > Equine Department > Equine Clinic |
| DDC: | 570 Life sciences; biology 610 Medicine & health 600 Technology 630 Agriculture |
| Language: | English |
| Date: | 2012 |
| Deposited On: | 26 Jul 2012 10:24 |
| Last Modified: | 15 Feb 2013 10:20 |
| Publisher: | Wiley-Blackwell |
| ISSN: | 1467-2987 |
| Publisher DOI: | 10.1111/j.1467-2995.2012.00741.x |
| Related URLs: | http://www.zora.uzh.ch/59408/ |
| PubMed ID: | 22726234 |
Users (please log in): suggest update or correction for this item
Repository Staff Only: item control page