Assessment of vascular contrast and depiction of stenoses in abdominopelvic and lower extremity vasculature: comparison of dual-energy MDCT with digital subtraction angiography


Huang, Steven Y; Nelson, Rendon C; Miller, Michael J; Kim, Charles Y; Lawson, Jeffrey H; Husarik, Daniela B; Boll, Daniel T (2012). Assessment of vascular contrast and depiction of stenoses in abdominopelvic and lower extremity vasculature: comparison of dual-energy MDCT with digital subtraction angiography. Academic Radiology, 19(9):1149-1157.

Abstract

RATIONALE AND OBJECTIVES: To assess whether dual-energy computed tomography (DECT) multidetector computed tomography (MDCT) angiography improves vascular contrast beyond MDCT angiography and digital subtraction angiography (DSA) while preserving the ability to precisely characterize stenoses, using DSA as reference standard. MATERIALS AND METHODS: This prospective, Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study was performed on 25 patients referred for lower extremity DECT angiography and subsequent DSA. Spectral data were postprocessed to create single-energy 120 kVp (MDCT series) and iodine-only (DECT series) datasets. The arterial tree was subdivided into 11 anatomical levels. Contrast-to-noise ratios (CNR) and corresponding coefficient -of variation (CV) of patent vessel segments were evaluated for DECT, MDCT, and DSA using analysis of variance comparisons. Degree of stenoses was determined for DECT, MDCT, and DSA and correlated with t-test, bivariate Pearson comparisons, and Bland-Altman plots. RESULTS: Patent vasculature comprised 230 vessel segments. From infrarenal aorta to distal femoral arteries, DECT showed higher CNR compared to DSA and MDCT (P < .05); distal to the popliteal arteries, DSA achieved higher CNR (P < .05). Analyses of contrast homogeneity showed minimal CV above the knee for MDCT (≤9%) and for DSA below the knee (≤7%). Stenotic vasculature comprised 33 segments. Significant correlations of stenosis severity were found comparing DECT and MDCT with DSA as reference standard showing a 0.04-fold mean underestimation of stenoses on MDCT and no detectable mean variation on DECT compared with DSA. CONCLUSION: DECT angiography improved contrast in vascular abdominopelvic and thigh distributions beyond MDCT angiography and DSA while preserving the ability to precisely assess severity of stenoses, using DSA as an accepted reference standard.

Abstract

RATIONALE AND OBJECTIVES: To assess whether dual-energy computed tomography (DECT) multidetector computed tomography (MDCT) angiography improves vascular contrast beyond MDCT angiography and digital subtraction angiography (DSA) while preserving the ability to precisely characterize stenoses, using DSA as reference standard. MATERIALS AND METHODS: This prospective, Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study was performed on 25 patients referred for lower extremity DECT angiography and subsequent DSA. Spectral data were postprocessed to create single-energy 120 kVp (MDCT series) and iodine-only (DECT series) datasets. The arterial tree was subdivided into 11 anatomical levels. Contrast-to-noise ratios (CNR) and corresponding coefficient -of variation (CV) of patent vessel segments were evaluated for DECT, MDCT, and DSA using analysis of variance comparisons. Degree of stenoses was determined for DECT, MDCT, and DSA and correlated with t-test, bivariate Pearson comparisons, and Bland-Altman plots. RESULTS: Patent vasculature comprised 230 vessel segments. From infrarenal aorta to distal femoral arteries, DECT showed higher CNR compared to DSA and MDCT (P < .05); distal to the popliteal arteries, DSA achieved higher CNR (P < .05). Analyses of contrast homogeneity showed minimal CV above the knee for MDCT (≤9%) and for DSA below the knee (≤7%). Stenotic vasculature comprised 33 segments. Significant correlations of stenosis severity were found comparing DECT and MDCT with DSA as reference standard showing a 0.04-fold mean underestimation of stenoses on MDCT and no detectable mean variation on DECT compared with DSA. CONCLUSION: DECT angiography improved contrast in vascular abdominopelvic and thigh distributions beyond MDCT angiography and DSA while preserving the ability to precisely assess severity of stenoses, using DSA as an accepted reference standard.

Citations

10 citations in Web of Science®
9 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2012
Deposited On:14 Dec 2012 09:31
Last Modified:05 Apr 2016 16:11
Publisher:Elsevier
ISSN:1076-6332
Publisher DOI:https://doi.org/10.1016/j.acra.2012.04.014
PubMed ID:22743115

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations