UZH-Logo

Maintenance Infos

Performance of a 200-MHz cryogenic RF probe designed for MRI and MRS of the murine brain


Ratering, D; Baltes, C; Nordmeyer-Massner, J A; Marek, D; Rudin, M (2008). Performance of a 200-MHz cryogenic RF probe designed for MRI and MRS of the murine brain. Magnetic Resonance in Medicine, 59(6):1440-1447.

Abstract

A cryogenic 200-MHz RF transmit/receive probe (CryoProbe) made of copper and designed for murine brain studies is described. The probe operates at 30K and its performance was compared to a home-made surface coil of equal dimensions and a mouse head volume resonator, both operating at room temperature (RT). Since for small volumes of tissue interrogated (<5 mL) sample noise and thermal noise of the receiver are of comparable magnitude, considerable noise reduction can be achieved by cooling of the receiver system, e.g., using cold helium gas. The effect of temperature lowering on the signal-to-noise ratio (SNR) was assessed in phantom and in vivo murine brain studies using conventional MRI sequences (spin and gradient echo) and single voxel MR spectroscopy. Consistent sensitivity increases were observed for the CryoProbe. SNR increases by a factor 2 for the phantom experiments and by factors of 1.8 to 1.9 for in vivo experiments when compared to the RT surface coil for both MRI and MRS experiments. These results are in good agreement with estimated SNR gains for a circular surface coil probe cooled to 30K. The use of a cryogenic probe represents an economically attractive option to enhance the sensitivity in small animal MRI/MRS.

A cryogenic 200-MHz RF transmit/receive probe (CryoProbe) made of copper and designed for murine brain studies is described. The probe operates at 30K and its performance was compared to a home-made surface coil of equal dimensions and a mouse head volume resonator, both operating at room temperature (RT). Since for small volumes of tissue interrogated (<5 mL) sample noise and thermal noise of the receiver are of comparable magnitude, considerable noise reduction can be achieved by cooling of the receiver system, e.g., using cold helium gas. The effect of temperature lowering on the signal-to-noise ratio (SNR) was assessed in phantom and in vivo murine brain studies using conventional MRI sequences (spin and gradient echo) and single voxel MR spectroscopy. Consistent sensitivity increases were observed for the CryoProbe. SNR increases by a factor 2 for the phantom experiments and by factors of 1.8 to 1.9 for in vivo experiments when compared to the RT surface coil for both MRI and MRS experiments. These results are in good agreement with estimated SNR gains for a circular surface coil probe cooled to 30K. The use of a cryogenic probe represents an economically attractive option to enhance the sensitivity in small animal MRI/MRS.

Citations

33 citations in Web of Science®
37 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 09 Dec 2008
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
04 Faculty of Medicine > Institute of Pharmacology and Toxicology
Dewey Decimal Classification:570 Life sciences; biology
170 Ethics
610 Medicine & health
Language:English
Date:2008
Deposited On:09 Dec 2008 15:08
Last Modified:05 Apr 2016 12:38
Publisher:Wiley-Blackwell
ISSN:0740-3194
Publisher DOI:10.1002/mrm.21629
PubMed ID:18421696
Permanent URL: http://doi.org/10.5167/uzh-6842

Download

[img]
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations