Cardiac proton spectroscopy using large coil arrays


Weiss, Kilian; Martini, Nicola; Boesiger, Peter; Kozerke, Sebastian (2013). Cardiac proton spectroscopy using large coil arrays. NMR in Biomedicine, 26(3):276-284.

Abstract

Large coil arrays are widely used in clinical routine for cardiovascular imaging providing extended spatial coverage and enabling accelerated acquisition using parallel imaging approaches. This work investigates the use of large coil arrays in single-voxel cardiac spectroscopy for the detection of myocardial creatine and triglyceride content. For this purpose, a navigator-gated and cardiac-triggered point-resolved spectroscopy sequence was implemented, and data obtained in 11 healthy volunteers using 32- and 5-element coil arrays were compared. For combination of the individual coil element signals, four strategies were evaluated differing in the manner of estimation of the complex coil weights and the amount of additional information required for coil combination. In all volunteers, and with both the 32- and 5-channel coil arrays, triglyceride-to-water (0.44 ± 0.19% and 0.45 ± 0.17%) and total creatine-to-water (0.05 ± 0.02% and 0.05 ± 0.01%) contents were computed. The values were found to agree well, showing an intraclass correlation coefficient of 0.76 (p < 0.003). The results revealed a gain in signal-to-noise ratio of approximately 24% with the 32-channel coil relative to the 5-channel array. The findings may foster the integration of cardiac spectroscopy into clinical practice using large coil arrays, provided that appropriate reconstruction algorithms are implemented.

Large coil arrays are widely used in clinical routine for cardiovascular imaging providing extended spatial coverage and enabling accelerated acquisition using parallel imaging approaches. This work investigates the use of large coil arrays in single-voxel cardiac spectroscopy for the detection of myocardial creatine and triglyceride content. For this purpose, a navigator-gated and cardiac-triggered point-resolved spectroscopy sequence was implemented, and data obtained in 11 healthy volunteers using 32- and 5-element coil arrays were compared. For combination of the individual coil element signals, four strategies were evaluated differing in the manner of estimation of the complex coil weights and the amount of additional information required for coil combination. In all volunteers, and with both the 32- and 5-channel coil arrays, triglyceride-to-water (0.44 ± 0.19% and 0.45 ± 0.17%) and total creatine-to-water (0.05 ± 0.02% and 0.05 ± 0.01%) contents were computed. The values were found to agree well, showing an intraclass correlation coefficient of 0.76 (p < 0.003). The results revealed a gain in signal-to-noise ratio of approximately 24% with the 32-channel coil relative to the 5-channel array. The findings may foster the integration of cardiac spectroscopy into clinical practice using large coil arrays, provided that appropriate reconstruction algorithms are implemented.

Citations

6 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2013
Deposited On:14 Feb 2013 09:55
Last Modified:05 Apr 2016 16:26
Publisher:Wiley-Blackwell
ISSN:0952-3480
Publisher DOI:https://doi.org/10.1002/nbm.2845
PubMed ID:22933454

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations