Remodeling leads to distinctly more intimal hyperplasia in coronary than in infrainguinal vein grafts


Zilla, Peter; Moodley, Loven; Scherman, Jacques; Krynauw, Hugo; Kortsmit, Jeroen; Human, Paul; Wolf, Michael F; Franz, Thomas (2012). Remodeling leads to distinctly more intimal hyperplasia in coronary than in infrainguinal vein grafts. Journal of Vascular Surgery, 55(6):1734-1741.

Abstract

BACKGROUND: Flow patterns and shear forces in native coronary arteries are more protective against neointimal hyperplasia than those in femoral arteries. Yet, the caliber mismatch with their target arteries makes coronary artery bypass grafts more likely to encounter intimal hyperplasia than their infrainguinal counterparts due to the resultant slow flow velocity and decreased wall stress. To allow a site-specific, flow-related comparison of remodeling behavior, saphenous vein bypass grafts were simultaneously implanted in femoral and coronary positions.
METHODS: Saphenous vein grafts were concomitantly implanted as coronary and femoral bypass grafts using a senescent nonhuman primate model. Duplex ultrasound-based blood flow velocity profiles and vein graft and target artery dimensions were correlated with dimensional and histomorphologic graft remodeling in large, senescent Chacma baboons (n = 8; 28.1 ± 4.9 kg) during a 24-week period.
RESULTS: At implantation, the cross-sectional quotient (Q(c)) between target arteries and vein grafts was 0.62 ± 0.10 for femoral grafts vs 0.17 ± 0.06 for coronary grafts, resulting in a dimensional graft-to-artery mismatch 3.6 times higher (P < .0001) in coronary grafts. Together with different velocity profiles, these site-specific dimensional discrepancies resulted in a 57.9% ± 19.4% lower maximum flow velocity (P = .0048), 48.1% ± 23.6% lower maximal cycling wall shear stress (P = .012), and 62.2% ± 21.2% lower mean velocity (P = .007) in coronary grafts. After 24 weeks, the luminal diameter of all coronary grafts had contracted by 63%, from an inner diameter of 4.49 ± 0.60 to 1.68 ± 0.63 mm (P < .0001; subintimal diameter: -41.5%; P = .002), whereas 57% of the femoral interposition grafts had dilated by 31%, from 4.21 ± 0.25 to 5.53 ± 1.30 mm (P = .020). Neointimal tissue was 2.3 times thicker in coronary than in femoral grafts (561 ± 73 vs 240 ± 149 μm; P = .001). Overall, the luminal area of coronary grafts was an average of 4.1 times smaller than that of femoral grafts.
CONCLUSIONS: Although coronary and infrainguinal bypass surgery uses saphenous veins as conduits, they undergo significantly different remodeling processes in these two anatomic positions.

Abstract

BACKGROUND: Flow patterns and shear forces in native coronary arteries are more protective against neointimal hyperplasia than those in femoral arteries. Yet, the caliber mismatch with their target arteries makes coronary artery bypass grafts more likely to encounter intimal hyperplasia than their infrainguinal counterparts due to the resultant slow flow velocity and decreased wall stress. To allow a site-specific, flow-related comparison of remodeling behavior, saphenous vein bypass grafts were simultaneously implanted in femoral and coronary positions.
METHODS: Saphenous vein grafts were concomitantly implanted as coronary and femoral bypass grafts using a senescent nonhuman primate model. Duplex ultrasound-based blood flow velocity profiles and vein graft and target artery dimensions were correlated with dimensional and histomorphologic graft remodeling in large, senescent Chacma baboons (n = 8; 28.1 ± 4.9 kg) during a 24-week period.
RESULTS: At implantation, the cross-sectional quotient (Q(c)) between target arteries and vein grafts was 0.62 ± 0.10 for femoral grafts vs 0.17 ± 0.06 for coronary grafts, resulting in a dimensional graft-to-artery mismatch 3.6 times higher (P < .0001) in coronary grafts. Together with different velocity profiles, these site-specific dimensional discrepancies resulted in a 57.9% ± 19.4% lower maximum flow velocity (P = .0048), 48.1% ± 23.6% lower maximal cycling wall shear stress (P = .012), and 62.2% ± 21.2% lower mean velocity (P = .007) in coronary grafts. After 24 weeks, the luminal diameter of all coronary grafts had contracted by 63%, from an inner diameter of 4.49 ± 0.60 to 1.68 ± 0.63 mm (P < .0001; subintimal diameter: -41.5%; P = .002), whereas 57% of the femoral interposition grafts had dilated by 31%, from 4.21 ± 0.25 to 5.53 ± 1.30 mm (P = .020). Neointimal tissue was 2.3 times thicker in coronary than in femoral grafts (561 ± 73 vs 240 ± 149 μm; P = .001). Overall, the luminal area of coronary grafts was an average of 4.1 times smaller than that of femoral grafts.
CONCLUSIONS: Although coronary and infrainguinal bypass surgery uses saphenous veins as conduits, they undergo significantly different remodeling processes in these two anatomic positions.

Citations

7 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2012
Deposited On:15 Feb 2013 12:07
Last Modified:05 Apr 2016 16:27
Publisher:Elsevier
ISSN:0741-5214
Publisher DOI:https://doi.org/10.1016/j.jvs.2011.11.057
PubMed ID:22386141

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations