Dynamic measurement of the height and volume of migrating cells by a novel fluorescence microscopy technique


Bottier, Celine; Gabella, Chiara; Vianay, Benoît; Buscemi, Lara; Sbalzarini, Ivo F; Meister, Jean-Jacques; Verkhovsky, Alexander B (2011). Dynamic measurement of the height and volume of migrating cells by a novel fluorescence microscopy technique. Lab on a chip, 11:3855-3863.

Abstract

We propose a new technique to measure the volume of adherent migrating cells. The method is based on a negative staining where a fluorescent, non cell-permeant dye is added to the extracellular medium. The specimen is observed with a conventional fluorescence microscope in a chamber of uniform height. Given that the fluorescence signal depends on the thickness of the emitting layer, the objects excluding the fluorescent dye (i.e., cells) appear dark, and the decrease of the fluorescent signal with respect to the background is expected to give information about the height and the volume of the object. Using a glass microfabricated pattern with steps of defined heights, we show that the drop in fluorescence intensity is indeed proportional to the height of the step and obtain calibration curves relating fluorescence intensity to height. The technique, termed fluorescence displacement method, is further validated by comparing our measurements with the ones obtained by atomic force microscopy (AFM). We apply our method to measure the real-time volume dynamics of migrating fish epidermal keratocytes subjected to osmotic stress. The fluorescence displacement technique allows fast and precise monitoring of cell height and volume, thus providing a valuable tool for characterizing the three-dimensional behaviour of migrating cells.

We propose a new technique to measure the volume of adherent migrating cells. The method is based on a negative staining where a fluorescent, non cell-permeant dye is added to the extracellular medium. The specimen is observed with a conventional fluorescence microscope in a chamber of uniform height. Given that the fluorescence signal depends on the thickness of the emitting layer, the objects excluding the fluorescent dye (i.e., cells) appear dark, and the decrease of the fluorescent signal with respect to the background is expected to give information about the height and the volume of the object. Using a glass microfabricated pattern with steps of defined heights, we show that the drop in fluorescence intensity is indeed proportional to the height of the step and obtain calibration curves relating fluorescence intensity to height. The technique, termed fluorescence displacement method, is further validated by comparing our measurements with the ones obtained by atomic force microscopy (AFM). We apply our method to measure the real-time volume dynamics of migrating fish epidermal keratocytes subjected to osmotic stress. The fluorescence displacement technique allows fast and precise monitoring of cell height and volume, thus providing a valuable tool for characterizing the three-dimensional behaviour of migrating cells.

Citations

10 citations in Web of Science®
11 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

70 downloads since deposited on 22 Jun 2013
42 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:Special Collections > SystemsX.ch
Special Collections > SystemsX.ch > Interdisciplinary PhD Projects
Dewey Decimal Classification:570 Life sciences; biology
Language:English
Date:2011
Deposited On:22 Jun 2013 12:53
Last Modified:05 Apr 2016 16:49
Publisher:RSC Publishing
ISSN:1473-0189
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1039/C1LC20807A
Permanent URL: https://doi.org/10.5167/uzh-78699

Download

[img]
Preview
Filetype: PDF
Size: 10MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations