Evaluation of esophageal high-resolution manometry in awake and sedated dogs


Kempf, J; Heinrich, H; Reusch, C E; Kook, P H (2013). Evaluation of esophageal high-resolution manometry in awake and sedated dogs. American Journal of Veterinary Research, 74(6):895-900.

Abstract

Objective-To evaluate the use of high-resolution manometry (HRM) in awake and sedated dogs and to assess potential effects of a standard sedation protocol. Animals-22 Beagles. Procedures-An HRM catheter with 36 pressure sensors was inserted intranasally in each dog. After an adaption period of 5 minutes, each set of measurements included 5 swallows of a liquid and 5 swallows of a solid bolus. Measurements were repeated 30 minutes after IM administration of buprenorphine and acepromazine. Results-HRM was successfully performed in 14 dogs. Data sets of 8 dogs were adequate for analysis. For the upper esophageal sphincter, median values of baseline pressure, residual pressure, relaxation time to nadir, and relaxation duration were determined for awake and sedated dogs for liquid and solid swallows. For the tubular portion of the esophagus, median values of peristaltic contractile integral, bolus transit time, and contractile front velocity were determined for awake and sedated dogs for liquid and solid swallows. For the lower esophageal sphincter, median values of baseline pressure and residual pressure were determined for awake and sedated dogs for liquid and solid swallows. Significant differences (awake vs sedated) were found for the upper esophageal sphincter residual pressure (liquid swallows), relaxation time to nadir (liquid swallows), bolus transit time (solid swallows), and contractile front velocity (solid swallows). Conclusions and Clinical Relevance-HRM was feasible for evaluation of esophageal function in most awake dogs. Although sedation in uncooperative patients may minimally influence results of some variables, an overall assessment of swallowing should be possible.

Objective-To evaluate the use of high-resolution manometry (HRM) in awake and sedated dogs and to assess potential effects of a standard sedation protocol. Animals-22 Beagles. Procedures-An HRM catheter with 36 pressure sensors was inserted intranasally in each dog. After an adaption period of 5 minutes, each set of measurements included 5 swallows of a liquid and 5 swallows of a solid bolus. Measurements were repeated 30 minutes after IM administration of buprenorphine and acepromazine. Results-HRM was successfully performed in 14 dogs. Data sets of 8 dogs were adequate for analysis. For the upper esophageal sphincter, median values of baseline pressure, residual pressure, relaxation time to nadir, and relaxation duration were determined for awake and sedated dogs for liquid and solid swallows. For the tubular portion of the esophagus, median values of peristaltic contractile integral, bolus transit time, and contractile front velocity were determined for awake and sedated dogs for liquid and solid swallows. For the lower esophageal sphincter, median values of baseline pressure and residual pressure were determined for awake and sedated dogs for liquid and solid swallows. Significant differences (awake vs sedated) were found for the upper esophageal sphincter residual pressure (liquid swallows), relaxation time to nadir (liquid swallows), bolus transit time (solid swallows), and contractile front velocity (solid swallows). Conclusions and Clinical Relevance-HRM was feasible for evaluation of esophageal function in most awake dogs. Although sedation in uncooperative patients may minimally influence results of some variables, an overall assessment of swallowing should be possible.

Citations

5 citations in Web of Science®
4 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 27 Jun 2013
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Language:English
Date:2013
Deposited On:27 Jun 2013 09:06
Last Modified:05 Apr 2016 16:49
Publisher:American Veterinary Medical Association
ISSN:0002-9645
Publisher DOI:https://doi.org/10.2460/ajvr.74.6.895
PubMed ID:23718658
Permanent URL: https://doi.org/10.5167/uzh-78719

Download

[img]
Filetype: PDF - Registered users only
Size: 252kB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.