Diffusion tensor imaging of the median nerve at 3.0T using different MR scanners: Agreement of FA and ADC measurements


Guggenberger, Roman; Nanz, Daniel; Bussmann, Lorenz; Chhabra, Avneesh; Fischer, Michael A; Hodler, Jürg; Pfirrmann, Christian W A; Andreisek, Gustav (2013). Diffusion tensor imaging of the median nerve at 3.0T using different MR scanners: Agreement of FA and ADC measurements. European Journal of Radiology, 82(10):e590-6.

Abstract

OBJECTIVE: To assess the agreement of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the median nerve on 3.0T MR scanners from different vendors. MATERIALS AND METHODS: IRB approved study including 16 healthy volunteers (9 women; mean age 30.6±5.3 years). Diffusion tensor imaging (DTI) of the dominant wrist was performed on three 3.0T MR scanners (GE, Siemens, Philips) using similar imaging protocols and vendor-proprietary hard- and software. Intra-, inter-reader and inter-vendor agreements were assessed. RESULTS: ICCs for intra-/inter-reader agreements ranged from 0.843-0.970/0.846-0.956 for FA, and 0.840-0.940/0.726-0.929 for ADC, respectively. ANOVA analysis identified significant differences for FA/ADC measurements among vendors (p<0.001/p<0.01, respectively). Overall mean values for FA were 0.63 (SD±0.1) and 0.999x10(-3)mm(2)/s (SD±0.134x10(-3)) for ADC. A significant negative measurement bias was found for FA values from the GE scanner (-0.05 and -0.07) and for ADC values from the Siemens scanner (-0.053 and -0.063x10(-3)mm(2)/s) as compared to the remainder vendors CONCLUSION: FA and ADC values of the median nerve obtained on different 3.0T MR scanners differ significantly, but are in comparison to the standard deviation of absolute values small enough to not have an impact on larger group studies or when substantial diffusion changes can be expected. However, caution is warranted in an individual patient when interpreting diffusion values from different scanner acquisitions.

OBJECTIVE: To assess the agreement of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the median nerve on 3.0T MR scanners from different vendors. MATERIALS AND METHODS: IRB approved study including 16 healthy volunteers (9 women; mean age 30.6±5.3 years). Diffusion tensor imaging (DTI) of the dominant wrist was performed on three 3.0T MR scanners (GE, Siemens, Philips) using similar imaging protocols and vendor-proprietary hard- and software. Intra-, inter-reader and inter-vendor agreements were assessed. RESULTS: ICCs for intra-/inter-reader agreements ranged from 0.843-0.970/0.846-0.956 for FA, and 0.840-0.940/0.726-0.929 for ADC, respectively. ANOVA analysis identified significant differences for FA/ADC measurements among vendors (p<0.001/p<0.01, respectively). Overall mean values for FA were 0.63 (SD±0.1) and 0.999x10(-3)mm(2)/s (SD±0.134x10(-3)) for ADC. A significant negative measurement bias was found for FA values from the GE scanner (-0.05 and -0.07) and for ADC values from the Siemens scanner (-0.053 and -0.063x10(-3)mm(2)/s) as compared to the remainder vendors CONCLUSION: FA and ADC values of the median nerve obtained on different 3.0T MR scanners differ significantly, but are in comparison to the standard deviation of absolute values small enough to not have an impact on larger group studies or when substantial diffusion changes can be expected. However, caution is warranted in an individual patient when interpreting diffusion values from different scanner acquisitions.

Citations

9 citations in Web of Science®
8 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2013
Deposited On:04 Jul 2013 07:14
Last Modified:05 Apr 2016 16:50
Publisher:Elsevier
ISSN:0720-048X
Publisher DOI:https://doi.org/10.1016/j.ejrad.2013.05.011
PubMed ID:23768611

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations