Permanent URL to this publication: http://dx.doi.org/10.5167/uzh-79

Puhan, M A; Bryant, D; Guyatt, G H; Heels-Ansdell, D; Schünemann, H J (2005). Internal consistency reliability is a poor predictor of responsiveness. Health and Quality of Life Outcomes, 3:33.

[img]
Preview
Published Version
PDF
327kB

Abstract

BACKGROUND: Whether responsiveness represents a measurement property of health-related quality of life (HRQL) instruments that is distinct from reliability and validity is an issue of debate. We addressed the claims of a recent study, which suggested that investigators could rely on internal consistency to reflect instrument responsiveness. METHODS: 516 patients with chronic obstructive pulmonary disease or knee injury participating in four longitudinal studies completed generic and disease-specific HRQL questionnaires before and after an intervention that impacted on HRQL. We used Pearson correlation coefficients and linear regression to assess the relationship between internal consistency reliability (expressed as Cronbach's alpha), instrument type (generic and disease-specific) and responsiveness (expressed as the standardised response mean, SRM). RESULTS: Mean Cronbach's alpha was 0.83 (SD 0.08) and mean SRM was 0.59 (SD 0.33). The correlation between Cronbach's alpha and SRMs was 0.10 (95% CI -0.12 to 0.32) across all studies. Cronbach's alpha alone did not explain variability in SRMs (p = 0.59, r2 = 0.01) whereas the type of instrument was a strong predictor of the SRM (p = 0.012, r2 = 0.37). In multivariable models applied to individual studies Cronbach's alpha consistently failed to predict SRMs (regression coefficients between -0.45 and 1.58, p-values between 0.15 and 0.98) whereas the type of instrument did predict SRMs (regression coefficients between -0.25 to -0.59, p-values between <0.01 and 0.05). CONCLUSION: Investigators must look to data other than internal consistency reliability to select a responsive instrument for use as an outcome in clinical trials.

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic and Policlinic for Internal Medicine
DDC:610 Medicine & health
Language:English
Date:2005
Deposited On:11 Feb 2008 12:12
Last Modified:02 Oct 2014 09:19
Publisher:BioMed Central
ISSN:1477-7525
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:10.1186/1477-7525-3-33
Official URL:http://www.hqlo.com/content/pdf/1477-7525-3-33.pdf