MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques


Imschweiler, Thomas; Haueisen, Harald; Kampmann, Gert; Rageth, Luzi; Seifert, Burkhardt; Rageth, Christoph; Freiwald, Bianka; Kubik-Huch, Rahel A (2014). MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques. European Radiology, 24(1):128-135.

Abstract

OBJECTIVES: To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. METHODS: We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. RESULTS: MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). CONCLUSION: MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. KEY POINTS: • Three vacuum-assisted breast biopsy (VAB) procedures were compared. • Technical success rates were high for all three VAB procedures. Medical complications were relatively low using all three VAB procedures. • The use of MRI-guided vacuum-assisted breast biopsy is growing.

OBJECTIVES: To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. METHODS: We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. RESULTS: MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). CONCLUSION: MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. KEY POINTS: • Three vacuum-assisted breast biopsy (VAB) procedures were compared. • Technical success rates were high for all three VAB procedures. Medical complications were relatively low using all three VAB procedures. • The use of MRI-guided vacuum-assisted breast biopsy is growing.

Citations

4 citations in Web of Science®
5 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2014
Deposited On:17 Oct 2013 14:10
Last Modified:05 Apr 2016 17:03
Publisher:Springer
ISSN:0938-7994
Publisher DOI:https://doi.org/10.1007/s00330-013-2989-5
PubMed ID:23979106

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations