Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography


Baumert, Bernhard; Plass, André; Bettex, Dominique; Alkadhi, Hatem; Desbiolles, Lotus; Wildermuth, Simon; Marincek, Borut; Boehm, Thomas (2005). Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography. Investigative Radiology, 40(10):637-647.

Abstract

BACKGROUND: We investigated the feasibility and image quality of dynamic cine-mode imaging of the normal aortic valve using multidetector row computed tomography (MDCT).
MATERIALS AND METHODS: We acquired contrast-enhanced retrospectively echocardiography (ECG)-gated cardiac MDCT datasets of 35 patients (mean age, 62 years; range, 53-77) who received a transoesophageal echocardiography (TOE) precedent to cardiac bypass graft surgery. Twenty data sets in 5% steps of the R-R interval were reconstructed, and data analysis was performed using a 4D software. Read-out of the MDCT data was performed in parallel and perpendicular planes, similar to TOE standard planes, by 2 independent, blinded readers using a 4-point Likert scale (best score: 4) for the following parameters: image quality of the aortic valve components, contrast media enhancement, contrast media inflow related artifacts, and ECG gating-related artifacts. The aortic valve area (AVA) was measured planimetrically and was compared between TOE and MDCT.
RESULTS: The best phase for assessing the open valve using MDCT was at 5% and the closed valve at 65% of the cardiac cycle. The mean image quality scores for cine-mode MDCT ranged between 3.26 and 3.75, with inter-reader agreements ranging between good (kappa = 0.723) and excellent (kappa = 1.00). They did not differ significantly from TOE scores for assessment of the closed and open valve. In transitional phases (close-to-open and open-to-close) TOE performed significantly better when compared with static MDCT images, whereas no significant difference was present between cine-mode presentation of MDCT and TOE. Planimetric AVA measurements correlated significantly between TOE and MDCT (Pearson correlation coefficient, r = 0.96; P < 0.0001). Contrast media inflow-related and ECG gating related artifacts were rated as slightly compromising (scores 3.24 and 3.21).
CONCLUSION: Retrospectively ECG-gated MDCT offers a noninvasive, accurate, and dynamic imaging method for quantitative and qualitative evaluation of the normal aortic valve allowing determination of morphology and function throughout the cardiac cycle. Further studies regarding assessment of diseased valves are necessary.

Abstract

BACKGROUND: We investigated the feasibility and image quality of dynamic cine-mode imaging of the normal aortic valve using multidetector row computed tomography (MDCT).
MATERIALS AND METHODS: We acquired contrast-enhanced retrospectively echocardiography (ECG)-gated cardiac MDCT datasets of 35 patients (mean age, 62 years; range, 53-77) who received a transoesophageal echocardiography (TOE) precedent to cardiac bypass graft surgery. Twenty data sets in 5% steps of the R-R interval were reconstructed, and data analysis was performed using a 4D software. Read-out of the MDCT data was performed in parallel and perpendicular planes, similar to TOE standard planes, by 2 independent, blinded readers using a 4-point Likert scale (best score: 4) for the following parameters: image quality of the aortic valve components, contrast media enhancement, contrast media inflow related artifacts, and ECG gating-related artifacts. The aortic valve area (AVA) was measured planimetrically and was compared between TOE and MDCT.
RESULTS: The best phase for assessing the open valve using MDCT was at 5% and the closed valve at 65% of the cardiac cycle. The mean image quality scores for cine-mode MDCT ranged between 3.26 and 3.75, with inter-reader agreements ranging between good (kappa = 0.723) and excellent (kappa = 1.00). They did not differ significantly from TOE scores for assessment of the closed and open valve. In transitional phases (close-to-open and open-to-close) TOE performed significantly better when compared with static MDCT images, whereas no significant difference was present between cine-mode presentation of MDCT and TOE. Planimetric AVA measurements correlated significantly between TOE and MDCT (Pearson correlation coefficient, r = 0.96; P < 0.0001). Contrast media inflow-related and ECG gating related artifacts were rated as slightly compromising (scores 3.24 and 3.21).
CONCLUSION: Retrospectively ECG-gated MDCT offers a noninvasive, accurate, and dynamic imaging method for quantitative and qualitative evaluation of the normal aortic valve allowing determination of morphology and function throughout the cardiac cycle. Further studies regarding assessment of diseased valves are necessary.

Citations

19 citations in Web of Science®
26 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Institute of Anesthesiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2005
Deposited On:18 Mar 2014 16:07
Last Modified:05 Apr 2016 17:38
Publisher:Lippincott, Williams & Wilkins
ISSN:0020-9996
Publisher DOI:https://doi.org/10.1097/01.rli.0000178363.79489.ef
Official URL:http://journals.lww.com/investigativeradiology/Abstract/2005/10000/Dynamic_Cine_Mode_Imaging_of_the_Normal_Aortic.2.aspx
PubMed ID:16189432

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations