UZH-Logo

Maintenance Infos

Impact of Three-Dimensional Imaging and Pressure Recovery on Echocardiographic Evaluation of Severe Aortic Stenosis: A Pilot Study - Zurich Open Repository and Archive


Stähli, Barbara E; Abouelnour, Amr; Nguyen, Thi Dan Linh; Vecchiati, Alessandra; Maier, Willibald; Lüscher, Thomas F; Frauenfelder, Thomas; Tanner, Felix C (2014). Impact of Three-Dimensional Imaging and Pressure Recovery on Echocardiographic Evaluation of Severe Aortic Stenosis: A Pilot Study. Echocardiography, 31(8):1006-1016.

Abstract

AIMS: In patients with aortic stenosis (AS), echocardiographic grading of stenosis severity is important, in particular for transcatheter aortic valve implantation (TAVI). Three-dimensional (3D) echocardiography and correction for pressure recovery (PR) by energy loss index (ELI) may improve aortic valve area (AVA) calculation.

METHODS AND RESULTS: Thirty-nine patients with severe AS evaluated for TAVI were included. Left ventricular outflow tract (LVOT) and ascending aorta (AA) cross-sectional area were determined in transthoracic two-dimensional echocardiography (2DTTE), 2D transesophageal echocardiography (TEE), 3DTEE, and multislice computed tomography (MSCT). AVA was calculated by the continuity equation and corrected for PR. ELI was determined as [(AVA × AA)/(AA - AVA)]/body surface area. LVOT area was 2.41 ± 0.17 cm(2) calculated using 2DTTE, 2.82 ± 0.16 cm(2) calculated using 2DTEE, 3.96 ± 0.14 cm(2) planimetered in 3DTEE, and 4.47 ± 0.18 cm(2) planimetered in MSCT (P < 0.001). AA area was 4.62 ± 0.23 cm(2) calculated using 2DTTE, 4.64 ± 0.23 cm(2) calculated using 2DTEE, 5.35 ± 0.25 cm(2) planimetered in 3DTEE, and 6.56 ± 0.31 cm(2) planimetered in MSCT (P < 0.001). Indexed aortic valve area (AVAI) calculated by 2DTTE and 2DTEE was smaller (0.27 ± 0.02 cm(2) /m(2) and 0.32 ± 0.02 cm(2) /m(2) ) compared to 3DTEE (0.45 ± 0.02 cm(2) /m(2) ; P < 0.001). When AVAI determined by 3DTEE was corrected for PR by calculation of ELI, there was a further increase (0.52 ± 0.03 cm(2) /m(2) ; P < 0.001), and 10/36 (27.8%) patients were reclassified to moderate AS.

CONCLUSION: Three-dimensional TEE is more accurate than 2DTTE and 2DTEE for determining LVOT and AA dimensions. When AS severity is determined by 3DTEE and corrected for PR using the 3D values, it needs to be reclassified from severe to moderate in almost a third of patients.

Abstract

AIMS: In patients with aortic stenosis (AS), echocardiographic grading of stenosis severity is important, in particular for transcatheter aortic valve implantation (TAVI). Three-dimensional (3D) echocardiography and correction for pressure recovery (PR) by energy loss index (ELI) may improve aortic valve area (AVA) calculation.

METHODS AND RESULTS: Thirty-nine patients with severe AS evaluated for TAVI were included. Left ventricular outflow tract (LVOT) and ascending aorta (AA) cross-sectional area were determined in transthoracic two-dimensional echocardiography (2DTTE), 2D transesophageal echocardiography (TEE), 3DTEE, and multislice computed tomography (MSCT). AVA was calculated by the continuity equation and corrected for PR. ELI was determined as [(AVA × AA)/(AA - AVA)]/body surface area. LVOT area was 2.41 ± 0.17 cm(2) calculated using 2DTTE, 2.82 ± 0.16 cm(2) calculated using 2DTEE, 3.96 ± 0.14 cm(2) planimetered in 3DTEE, and 4.47 ± 0.18 cm(2) planimetered in MSCT (P < 0.001). AA area was 4.62 ± 0.23 cm(2) calculated using 2DTTE, 4.64 ± 0.23 cm(2) calculated using 2DTEE, 5.35 ± 0.25 cm(2) planimetered in 3DTEE, and 6.56 ± 0.31 cm(2) planimetered in MSCT (P < 0.001). Indexed aortic valve area (AVAI) calculated by 2DTTE and 2DTEE was smaller (0.27 ± 0.02 cm(2) /m(2) and 0.32 ± 0.02 cm(2) /m(2) ) compared to 3DTEE (0.45 ± 0.02 cm(2) /m(2) ; P < 0.001). When AVAI determined by 3DTEE was corrected for PR by calculation of ELI, there was a further increase (0.52 ± 0.03 cm(2) /m(2) ; P < 0.001), and 10/36 (27.8%) patients were reclassified to moderate AS.

CONCLUSION: Three-dimensional TEE is more accurate than 2DTTE and 2DTEE for determining LVOT and AA dimensions. When AS severity is determined by 3DTEE and corrected for PR using the 3D values, it needs to be reclassified from severe to moderate in almost a third of patients.

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
Dewey Decimal Classification:610 Medicine & health
Date:2014
Deposited On:18 Mar 2014 15:58
Last Modified:05 Apr 2016 17:38
Publisher:Wiley-Blackwell
ISSN:0742-2822
Publisher DOI:https://doi.org/10.1111/echo.12509
PubMed ID:24447293

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations