Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography


Guggenberger, Roman; Pfirrmann, Christian W A; Koch, Peter P; Buck, Florian M (2014). Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography. American Journal of Roentgenology, 202(2):W161-W167.

Abstract

OBJECTIVE. The purpose of this article is to compare lower limb length and alignment measurements on supine CT, upright full-length radiography, and 3D models based on upright biplanar linear radiography.

SUBJECTS AND METHODS. This study involved 51 consecutive patients (22 men and 29 women; mean age, 68.8 years; range, 43-92 years) who were scheduled for total knee replacement. Lower limb length and alignment angle were measured on CT, upright full-length radiography, and 3D models based on biplanar linear radiography with standard and composed leg methods by two independent readers. Descriptive statistics of each modality were calculated. Measurements of different modalities were compared by paired Student t tests. Agreement between readers and modalities was assessed by Bland-Altman analyses.

RESULTS. Mean (± SD) limb lengths were 783 ± 56.1 mm (range, 639-927 mm), 785 ± 53.0 mm (range, 655-924 mm), 780 ± 55.4 mm (range, 633-921 mm), and 783 ± 55.9 mm (range, 636-924 mm) for CT, upright full-length radiography, and 3D models based on biplanar linear radiography standard and composed leg measurements, respectively. Mean alignment angles were 2.3° ± 5.5° (range, -12° to 20°) for CT, 2.5° ± 6.7° (range, -17° to 18°) for upright full-length radiography, and 3.4° ± 6.6° (range, -14° to 18°) for 3D models based on biplanar linear radiography. No significant differences among modalities for mean limb length were found when using composed leg measurements in biplanar linear radiography. Very small but significant mean differences in angle measurements were seen for CT (-1.1° ± 2.5) and upright full-length radiography (-0.9° ± 3.1) compared with biplanar linear radiography. Bland-Altman analyses showed no significant differences between readers, with the highest agreement for biplanar linear radiography length measurements.

CONCLUSION. Measurements on 3D models based on upright biplanar linear radiographs allow lower limb length and alignment angle measurements that are interchangeable with supine CT scans and upright full-length radiographs but with superior interreader agreement.

Abstract

OBJECTIVE. The purpose of this article is to compare lower limb length and alignment measurements on supine CT, upright full-length radiography, and 3D models based on upright biplanar linear radiography.

SUBJECTS AND METHODS. This study involved 51 consecutive patients (22 men and 29 women; mean age, 68.8 years; range, 43-92 years) who were scheduled for total knee replacement. Lower limb length and alignment angle were measured on CT, upright full-length radiography, and 3D models based on biplanar linear radiography with standard and composed leg methods by two independent readers. Descriptive statistics of each modality were calculated. Measurements of different modalities were compared by paired Student t tests. Agreement between readers and modalities was assessed by Bland-Altman analyses.

RESULTS. Mean (± SD) limb lengths were 783 ± 56.1 mm (range, 639-927 mm), 785 ± 53.0 mm (range, 655-924 mm), 780 ± 55.4 mm (range, 633-921 mm), and 783 ± 55.9 mm (range, 636-924 mm) for CT, upright full-length radiography, and 3D models based on biplanar linear radiography standard and composed leg measurements, respectively. Mean alignment angles were 2.3° ± 5.5° (range, -12° to 20°) for CT, 2.5° ± 6.7° (range, -17° to 18°) for upright full-length radiography, and 3.4° ± 6.6° (range, -14° to 18°) for 3D models based on biplanar linear radiography. No significant differences among modalities for mean limb length were found when using composed leg measurements in biplanar linear radiography. Very small but significant mean differences in angle measurements were seen for CT (-1.1° ± 2.5) and upright full-length radiography (-0.9° ± 3.1) compared with biplanar linear radiography. Bland-Altman analyses showed no significant differences between readers, with the highest agreement for biplanar linear radiography length measurements.

CONCLUSION. Measurements on 3D models based on upright biplanar linear radiographs allow lower limb length and alignment angle measurements that are interchangeable with supine CT scans and upright full-length radiographs but with superior interreader agreement.

Citations

3 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Date:2014
Deposited On:18 Mar 2014 16:01
Last Modified:05 Apr 2016 17:38
Publisher:American Roentgen Ray Society
ISSN:0361-803X
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.2214/AJR.13.10782
PubMed ID:24450698

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations