Reliability of tarsal bone segmentation and its contribution to MR kinematic analysis methods


Wolf, P; Luechinger, R; Stacoff, A; Boesiger, P; Stuessi, E (2007). Reliability of tarsal bone segmentation and its contribution to MR kinematic analysis methods. Computerized Medical Imaging and Graphics, 31(7):523-530.

Abstract

The purpose of this study was to determine the reliability of tarsal bone segmentation based on magnetic resonance (MR) imaging using commercially available software. All tarsal bones of five subjects were segmented five times each by two operators. Volumes and second moments of volume were calculated and used to determine the intra- as well as interoperator reproducibility. The results show that these morphological parameters had excellent interclass correlation coefficients (>0.997) indicating that the presented tarsal bone segmentation is a reliable procedure and that operators are in fact interchangeable. The consequences on differences in MR kinematic analysis methods of segmentation due to repetition were also determined. It became evident that one analysis method--fitting surface point clouds--was considerable less affected by repeated segmentation (cuboid: up to 0.2 degrees, other tarsal bones up to 0.1 degrees) compared to a method using principal axes (cuboid up to 6.7 degrees, other tarsal bones up to 0.8 degrees). Thus, the former method is recommended for investigations of tarsal bone kinematics by MR imaging.

The purpose of this study was to determine the reliability of tarsal bone segmentation based on magnetic resonance (MR) imaging using commercially available software. All tarsal bones of five subjects were segmented five times each by two operators. Volumes and second moments of volume were calculated and used to determine the intra- as well as interoperator reproducibility. The results show that these morphological parameters had excellent interclass correlation coefficients (>0.997) indicating that the presented tarsal bone segmentation is a reliable procedure and that operators are in fact interchangeable. The consequences on differences in MR kinematic analysis methods of segmentation due to repetition were also determined. It became evident that one analysis method--fitting surface point clouds--was considerable less affected by repeated segmentation (cuboid: up to 0.2 degrees, other tarsal bones up to 0.1 degrees) compared to a method using principal axes (cuboid up to 6.7 degrees, other tarsal bones up to 0.8 degrees). Thus, the former method is recommended for investigations of tarsal bone kinematics by MR imaging.

Citations

4 citations in Web of Science®
5 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2007
Deposited On:21 May 2014 07:19
Last Modified:05 Apr 2016 17:51
Publisher:Pergamon
ISSN:0895-6111
Publisher DOI:https://doi.org/10.1016/j.compmedimag.2007.06.009
PubMed ID:17689923

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations