Rapid and robust pulmonary proton ZTE imaging in the mouse


Weiger, Markus; Wu, Mingming; Wurnig, Moritz C; Kenkel, David; Jungraithmayr, Wolfgang; Boss, Andreas; Pruessmann, Klaas P (2014). Rapid and robust pulmonary proton ZTE imaging in the mouse. NMR in Biomedicine, 27(9):1129-1134.

Abstract

Pulmonary MRI is challenging because of the low proton density and rapid transverse relaxation in the lung associated with microscopic magnetic field inhomogeneities caused by tissue-air interfaces. Therefore, low signal is obtained in gradient and spin echo proton images. Alternatively, non-proton MRI using hyperpolarized gases or radial techniques with ultrashort or zero TE have been proposed to image the lung. Also with the latter approach, the general challenge remains to provide full coverage of the lung at sufficient spatial resolution, signal-to-noise ratio (SNR) and image quality within a reasonable scan time. This task is further aggravated by physiological motion and is particularly demanding in small animals, such as mice. In this work, three-dimensional (3D) zero echo time (ZTE) imaging is employed for efficient pulmonary MRI. Four protocols with different averaging and respiratory triggering schemes are developed and compared with respect to image quality and SNR. To address the critical issue of background signal in ZTE images, a subtraction approach is proposed, providing images virtually free of disturbing signal from nearby hardware parts. The protocols are tested for pulmonary MRI in six mice at 4.7 T, consistently providing images of high quality with a 3D isotropic resolution of 313 µm and SNR values in the lung between 8.0 and 18.5 within scan times between 1 min 21 s and 4 min 44 s. A generally high robustness of the ZTE approach against motion is observed, whilst respiratory triggering further improves the SNR and visibility of image details. The developed techniques are expected to enable efficient preclinical animal studies in the lung and will also be of importance for human applications. Further improvements are expected from radiofrequency (RF) coils with increased SNR and reduced background signal. Copyright © 2014 John Wiley & Sons, Ltd.

Pulmonary MRI is challenging because of the low proton density and rapid transverse relaxation in the lung associated with microscopic magnetic field inhomogeneities caused by tissue-air interfaces. Therefore, low signal is obtained in gradient and spin echo proton images. Alternatively, non-proton MRI using hyperpolarized gases or radial techniques with ultrashort or zero TE have been proposed to image the lung. Also with the latter approach, the general challenge remains to provide full coverage of the lung at sufficient spatial resolution, signal-to-noise ratio (SNR) and image quality within a reasonable scan time. This task is further aggravated by physiological motion and is particularly demanding in small animals, such as mice. In this work, three-dimensional (3D) zero echo time (ZTE) imaging is employed for efficient pulmonary MRI. Four protocols with different averaging and respiratory triggering schemes are developed and compared with respect to image quality and SNR. To address the critical issue of background signal in ZTE images, a subtraction approach is proposed, providing images virtually free of disturbing signal from nearby hardware parts. The protocols are tested for pulmonary MRI in six mice at 4.7 T, consistently providing images of high quality with a 3D isotropic resolution of 313 µm and SNR values in the lung between 8.0 and 18.5 within scan times between 1 min 21 s and 4 min 44 s. A generally high robustness of the ZTE approach against motion is observed, whilst respiratory triggering further improves the SNR and visibility of image details. The developed techniques are expected to enable efficient preclinical animal studies in the lung and will also be of importance for human applications. Further improvements are expected from radiofrequency (RF) coils with increased SNR and reduced background signal. Copyright © 2014 John Wiley & Sons, Ltd.

Citations

9 citations in Web of Science®
8 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Date:26 July 2014
Deposited On:13 Aug 2014 13:49
Last Modified:05 Apr 2016 18:00
Publisher:Wiley-Blackwell
ISSN:0952-3480
Publisher DOI:https://doi.org/10.1002/nbm.3161
PubMed ID:25066371

Download

Full text not available from this repository.View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations