Quantitative in vivo analysis of small bowel motility using MRI examinations in mice - proof of concept study


Bickelhaupt, S; Wurnig, M C; Lesurtel, M; Patak, M A; Boss, A (2015). Quantitative in vivo analysis of small bowel motility using MRI examinations in mice - proof of concept study. Laboratory Animals, 49(1):57-64.

Abstract

Small bowel motility analyses using magnetic resonance imaging (MRI) could reduce current invasive techniques in animal studies and comply with the 'three Rs' rule for human animal experimentation. Thus we investigated the feasibility of in vivo small bowel motility analyses in mice using dynamic MRI acquisitions. All experimental procedures were approved by the institutional animal care committee. Six C57BL/6 mice underwent MRI without additional preparation after isoflurane anaesthetization in the prone position on a 4.7 T small animal imager equipped with a linear polarized hydrogen birdcage whole-body mouse coil. Motility was assessed using a true fast imaging in a steady precession sequence in the coronal orientation (acquisition time per slice 512 ms, in-plane resolution 234 × 234 µm, matrix size 128 × 128, slice thickness 1 mm) over 30 s corresponding to 60 acquisitions. Motility was manually assessed measuring the small bowel diameter change over time. The resulting motility curves were analysed for the following parameters: contraction frequency per minute (cpm), maximal contraction amplitude (maximum to minimum [mm]), luminal diameter (mm) and luminal occlusion rate. Small bowel motility quantification was found to be possible in all animals with a mean small bowel contraction frequency of 10.67 cpm (SD ± 3.84), a mean amplitude of the contractions of 1.33 mm (SD ± 0.43) and a mean luminal diameter of 1.37 mm (SD ± 0.42). The mean luminal occlusion rate was 1.044 (SD ± 0.45%/100). The mean duration needed for a single motility assessment was 185 s (SD ± 54.02). Thus our study demonstrated the feasibility of an easy and time-sparing functional assessment for in vivo small bowel motility analyses in mice. This could improve the development of small animal models of intestinal diseases and provide a method similar to clinical MR examinations that is in concordance with the 'three Rs' for humane animal experimentation.

Abstract

Small bowel motility analyses using magnetic resonance imaging (MRI) could reduce current invasive techniques in animal studies and comply with the 'three Rs' rule for human animal experimentation. Thus we investigated the feasibility of in vivo small bowel motility analyses in mice using dynamic MRI acquisitions. All experimental procedures were approved by the institutional animal care committee. Six C57BL/6 mice underwent MRI without additional preparation after isoflurane anaesthetization in the prone position on a 4.7 T small animal imager equipped with a linear polarized hydrogen birdcage whole-body mouse coil. Motility was assessed using a true fast imaging in a steady precession sequence in the coronal orientation (acquisition time per slice 512 ms, in-plane resolution 234 × 234 µm, matrix size 128 × 128, slice thickness 1 mm) over 30 s corresponding to 60 acquisitions. Motility was manually assessed measuring the small bowel diameter change over time. The resulting motility curves were analysed for the following parameters: contraction frequency per minute (cpm), maximal contraction amplitude (maximum to minimum [mm]), luminal diameter (mm) and luminal occlusion rate. Small bowel motility quantification was found to be possible in all animals with a mean small bowel contraction frequency of 10.67 cpm (SD ± 3.84), a mean amplitude of the contractions of 1.33 mm (SD ± 0.43) and a mean luminal diameter of 1.37 mm (SD ± 0.42). The mean luminal occlusion rate was 1.044 (SD ± 0.45%/100). The mean duration needed for a single motility assessment was 185 s (SD ± 54.02). Thus our study demonstrated the feasibility of an easy and time-sparing functional assessment for in vivo small bowel motility analyses in mice. This could improve the development of small animal models of intestinal diseases and provide a method similar to clinical MR examinations that is in concordance with the 'three Rs' for humane animal experimentation.

Statistics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Visceral and Transplantation Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2015
Deposited On:04 Nov 2014 14:32
Last Modified:05 Apr 2016 18:27
Publisher:Sage Publications Ltd.
ISSN:0023-6772
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1177/0023677214553321
PubMed ID:25266965

Download

Full text not available from this repository.
View at publisher