Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonates - Zurich Open Repository and Archive


Bernet, Vera; Döll, Carsten; Cannizzaro, Vincenzo; Ersch, Jörg; Frey, Bernhard; Weiss, Markus (2008). Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonates. Pediatric Anesthesia (Paediatric Anaesthesia), 18(9):872-877.

Abstract

OBJECTIVES: Blood gas monitoring is necessary in treatment of critically ill neonates. Whereas SaO2 can be estimated by pulse oximetry, PaCO2 is still most often assessed from blood samples. AIM: To compare long time performance of an ear sensor for combined assessment of transcutaneous carbon dioxide (PtcCO2) and oxygen saturation (SpO2) (TOSCA Monitor; Radiometer, Switzerland) with a conventional PtcCO2 monitor (MicroGas 7650-500 rapid, Radiometer, Switzerland) in critically ill neonates. METHODS: Prospective, observational study. Twenty critically ill neonates were monitored for PtcCO2 and SpO2 using the Tosca and the MicroGas monitor for 24 h. TOSCA ear sensor was changed to the other ear lobe after 12 h and the MicroGas sensor four hourly on the trunk. Values obtained were compared with SaO2 and PaCO2 from arterial blood gas analysis using Bland-Altman analysis. Data are presented as median (range). RESULTS: Eighty-two paired measurements were obtained. Median age of the 20 patients was 4.5 days (1-26 days) and weight was 3.05 kg (0.98-3.95 kg). Bias and precision between PaCO2 and PtcCO2 were 0.14 and 1.45 kPa for the Tosca monitor and -0.08 and 1.2 kPa for the MicroGas monitor, respectively. The two biases were significantly different (P = 0.0036). SpO2 assessment by TOSCA was comparable to SaO2 values (bias 0.26% and precision 4.14%). CONCLUSION: The TOSCA monitor allows safe estimation of PtcCO2 and SaO2 in neonates. Measurements of PtcCO2 were less reliable with TOSCA compared with conventional monitoring but still allow assessing a trend of ventilation status in newborn patients.

Abstract

OBJECTIVES: Blood gas monitoring is necessary in treatment of critically ill neonates. Whereas SaO2 can be estimated by pulse oximetry, PaCO2 is still most often assessed from blood samples. AIM: To compare long time performance of an ear sensor for combined assessment of transcutaneous carbon dioxide (PtcCO2) and oxygen saturation (SpO2) (TOSCA Monitor; Radiometer, Switzerland) with a conventional PtcCO2 monitor (MicroGas 7650-500 rapid, Radiometer, Switzerland) in critically ill neonates. METHODS: Prospective, observational study. Twenty critically ill neonates were monitored for PtcCO2 and SpO2 using the Tosca and the MicroGas monitor for 24 h. TOSCA ear sensor was changed to the other ear lobe after 12 h and the MicroGas sensor four hourly on the trunk. Values obtained were compared with SaO2 and PaCO2 from arterial blood gas analysis using Bland-Altman analysis. Data are presented as median (range). RESULTS: Eighty-two paired measurements were obtained. Median age of the 20 patients was 4.5 days (1-26 days) and weight was 3.05 kg (0.98-3.95 kg). Bias and precision between PaCO2 and PtcCO2 were 0.14 and 1.45 kPa for the Tosca monitor and -0.08 and 1.2 kPa for the MicroGas monitor, respectively. The two biases were significantly different (P = 0.0036). SpO2 assessment by TOSCA was comparable to SaO2 values (bias 0.26% and precision 4.14%). CONCLUSION: The TOSCA monitor allows safe estimation of PtcCO2 and SaO2 in neonates. Measurements of PtcCO2 were less reliable with TOSCA compared with conventional monitoring but still allow assessing a trend of ventilation status in newborn patients.

Citations

9 citations in Web of Science®
9 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 20 Jan 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
Dewey Decimal Classification:610 Medicine & health
Date:2008
Deposited On:20 Jan 2009 13:15
Last Modified:05 Apr 2016 12:50
Publisher:Wiley-Blackwell
ISSN:1155-5645
Publisher DOI:https://doi.org/10.1111/j.1460-9592.2008.02661.x
PubMed ID:18768047

Download

Preview Icon on Download
Filetype: PDF - Registered users only
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations