Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses


Wimmer, Timea; Erdelt, Kurt-Jürgen; Eichberger, Marlis; Roos, Malgorzata; Edelhoff, Daniel; Stawarczyk, Bogna (2014). Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dental Materials Journal, 33(6):717-724.

Abstract

This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively cemented on a polymeric model and on a base metal alloy one. For the fracture load test the FDPs were loaded at the centre of the pontic (1 mm/min). The data were analyzed using descriptive statistics, two- and one-way ANOVA followed by post-hoc Scheffé test and Weibull statistics. Fracture loads were found to be affected by the choice of materials used for the abutment models. The fracture load for zirconia FDPs cemented on metal abutments was higher than on polymeric abutment group. In contrast, Telio CAD cemented on polymeric abutments presented higher fracture loads than group on base metal alloy support.

Abstract

This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively cemented on a polymeric model and on a base metal alloy one. For the fracture load test the FDPs were loaded at the centre of the pontic (1 mm/min). The data were analyzed using descriptive statistics, two- and one-way ANOVA followed by post-hoc Scheffé test and Weibull statistics. Fracture loads were found to be affected by the choice of materials used for the abutment models. The fracture load for zirconia FDPs cemented on metal abutments was higher than on polymeric abutment group. In contrast, Telio CAD cemented on polymeric abutments presented higher fracture loads than group on base metal alloy support.

Statistics

Citations

3 citations in Web of Science®
2 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 14 Jan 2015
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2014
Deposited On:14 Jan 2015 10:04
Last Modified:05 Apr 2016 18:48
Publisher:Japanese Society for Dental Materials and Devices
ISSN:0287-4547
Publisher DOI:https://doi.org/10.4012/dmj.2013-344

Download