Wireless 'mini' multichannel intraluminal impedance-pH: what is the optimal design of a miniature wireless device?


Heard, R; Sharma, N; Roberts, J; Castell, D; Pohl, D (2014). Wireless 'mini' multichannel intraluminal impedance-pH: what is the optimal design of a miniature wireless device? Diseases of the Esophagus, 27(5):424-427.

Abstract

Catheter-based methods for multichannel intraluminal impedance-pH monitoring are invasive and uncomfortable. The current alternative is a wireless system that clips to the esophageal mucosa, but which only measures pH. A shorter two-site wireless sensor that detects impedance and pH, and can be clipped to the esophagus, would be desirable. This study compares sensor positions and separations to determine the optimal configuration of a two-site wireless sensor. Records of 20 patients (10 on and 10 off proton pump inhibitor) who had ambulatory reflux testing with a multichannel intraluminal impedance-pH system (Sandhill Scientific Inc., Highlands Ranch, CO, USA) with six impedance and two pH sensors were reviewed. An investigator was blinded to four combinations of impedance channels plus pH. He read a 3-hour postprandial section from each of the combinations (total of 80 studies) and marked reflux episodes. Results were compared with his own interpretation of the full tracing. Two hundred and two total reflux episodes were analyzed, 113 acid (pH < 4) and 89 nonacid (pH > 4). Mean and median numbers of total reflux episodes were calculated. In the full study, the interpreter detected a mean of 10 reflux episodes per study. In the 5 cm and 7 cm, 3 cm and 7 cm, and 3 cm and 5 cm studies, the interpreter found a mean of 8.1, 11.1, and 9.8 reflux episodes per study, respectively. One-way analysis of variance yielded a P-value of 0.43. The trend of these preliminary findings suggests that the 3 cm and 5 cm site is the most sensitive and the 5 cm and 7 cm is the least, with the 3 cm and 7 cm site perhaps as the preferred location. The lack of a significant difference, at the very least, suggests that any of the 'mini' locations could be used. The small number of observations could have resulted in a Type II statistical error.

Abstract

Catheter-based methods for multichannel intraluminal impedance-pH monitoring are invasive and uncomfortable. The current alternative is a wireless system that clips to the esophageal mucosa, but which only measures pH. A shorter two-site wireless sensor that detects impedance and pH, and can be clipped to the esophagus, would be desirable. This study compares sensor positions and separations to determine the optimal configuration of a two-site wireless sensor. Records of 20 patients (10 on and 10 off proton pump inhibitor) who had ambulatory reflux testing with a multichannel intraluminal impedance-pH system (Sandhill Scientific Inc., Highlands Ranch, CO, USA) with six impedance and two pH sensors were reviewed. An investigator was blinded to four combinations of impedance channels plus pH. He read a 3-hour postprandial section from each of the combinations (total of 80 studies) and marked reflux episodes. Results were compared with his own interpretation of the full tracing. Two hundred and two total reflux episodes were analyzed, 113 acid (pH < 4) and 89 nonacid (pH > 4). Mean and median numbers of total reflux episodes were calculated. In the full study, the interpreter detected a mean of 10 reflux episodes per study. In the 5 cm and 7 cm, 3 cm and 7 cm, and 3 cm and 5 cm studies, the interpreter found a mean of 8.1, 11.1, and 9.8 reflux episodes per study, respectively. One-way analysis of variance yielded a P-value of 0.43. The trend of these preliminary findings suggests that the 3 cm and 5 cm site is the most sensitive and the 5 cm and 7 cm is the least, with the 3 cm and 7 cm site perhaps as the preferred location. The lack of a significant difference, at the very least, suggests that any of the 'mini' locations could be used. The small number of observations could have resulted in a Type II statistical error.

Statistics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Gastroenterology and Hepatology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:July 2014
Deposited On:11 Feb 2015 11:41
Last Modified:08 Dec 2017 11:07
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1120-8694
Publisher DOI:https://doi.org/10.1111/j.1442-2050.2012.01410.x
PubMed ID:22978791

Download

Full text not available from this repository.
View at publisher